Amperometric determination of L-malic acid in a flow injection analysis manifold using packed-bed enzyme reactors

被引:20
作者
Prodromidis, MI
TzouwaraKarayanni, SM
Karayannis, MI
Vadgama, P
Maines, A
机构
[1] UNIV IOANNINA,DEPT CHEM,ANALYT CHEM LAB,GR-45110 IOANNINA,GREECE
[2] UNIV MANCHESTER,HOPE HOSP,DEPT MED,SALFORD M6 8HD,LANCS,ENGLAND
关键词
amperometric malate determination; malate dehydrogenase and diaphorase reactors; flow injection analysis; fruits and vegetables;
D O I
10.1039/an9962100435
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzymic method for the determination of L-malic acid in fruits and vegetables is described, Malate dehydrogenase (MDH) and diaphorase (DI) were co-immobilized on aminopropyl-, isothiocyanate- and N-hydroxysuccinimide ester (N-HSE)-modified controlled-pore glass, which was then used for the construction of a packed-bed reactor, MDH catalyses the reaction between malate and NAD(+) and produces NADH, which converts hexacyanoferrate(III) into hexacyanoferrate(II) in the presence of the DI, Amperometric measurements with pure graphite electrodes in a fully automated flow injection manifold were used to monitor the concentration of hexacyanoferrate(II) at +0.3 V versus an Ag/AgCl reference electrode, The electrochemical behaviour of hexacyanoferrate(III), 2,6-dichlorophenolindophenol and p-benzoquinone was tested with cyclic voltammetry. Parameters such as working and immobilization pH, flow rate, sample size, temperature and NAD(+) and hexacyanoferrate(III) concentrations were investigated, The interference of various ions, amino acids and organic acids present in real samples was also studied, The calibration graph was linear for the range 2 x 10(-5)-4 x 10(-4) mol l(-1) malate, The reactors remained active for a period of more than 3 months under specified storage conditions, The maximum sample throughput was 30 h(-1) and the relative standard deviation of the method was better than 1.5% (n = 5), The mean relative error was 4% for fruits-and 2% for vegetables, The accuracy of the proposed method was tested by comparison of the results with those obtained by a reference method. Good correlation was attained, Recovery experiments showed results between 95 and 108%.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 27 条
[1]  
ALBMUIABED AM, 1989, ANAL CHIM ACTA, V221, P337
[2]   BIAMPEROMETRIC DETERMINATION OF GLYCEROL AND TRIGLYCERIDES WITH OPEN TUBULAR CARBON ELECTRODES IN FLOW STREAMS [J].
ATTIYAT, AS ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1979, 106 (02) :225-231
[3]  
BANASZAK LJ, 1975, ENZYMES, V11, P369
[4]   REAGENTLESS ENZYME ELECTRODES FOR ETHANOL, LACTATE, AND MALATE [J].
BLAEDEL, WJ ;
ENGSTROM, RC .
ANALYTICAL CHEMISTRY, 1980, 52 (11) :1691-1697
[5]  
CHELLER F, 1992, BIOSENSORS, P28
[6]   REDOX ELECTRODE FOR MONITORING DEHYDROGENASE-CATALYZED REACTIONS [J].
CHEN, SSH .
CLINICA CHIMICA ACTA, 1990, 190 (03) :129-137
[7]  
ENGLARD S, 1969, METHOD ENZYMOL, V13, P99
[8]  
FUMIO M, 1991, ANAL SCI, V7, P871
[9]  
GARDNER WH, 1966, SENSORY EFFECTS FOOD, P44
[10]  
GARDNER WH, 1966, SENSORY EFFECTS FOOD, pCH5