Amperometric determination of L-malic acid in a flow injection analysis manifold using packed-bed enzyme reactors

被引:20
作者
Prodromidis, MI
TzouwaraKarayanni, SM
Karayannis, MI
Vadgama, P
Maines, A
机构
[1] UNIV IOANNINA,DEPT CHEM,ANALYT CHEM LAB,GR-45110 IOANNINA,GREECE
[2] UNIV MANCHESTER,HOPE HOSP,DEPT MED,SALFORD M6 8HD,LANCS,ENGLAND
关键词
amperometric malate determination; malate dehydrogenase and diaphorase reactors; flow injection analysis; fruits and vegetables;
D O I
10.1039/an9962100435
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzymic method for the determination of L-malic acid in fruits and vegetables is described, Malate dehydrogenase (MDH) and diaphorase (DI) were co-immobilized on aminopropyl-, isothiocyanate- and N-hydroxysuccinimide ester (N-HSE)-modified controlled-pore glass, which was then used for the construction of a packed-bed reactor, MDH catalyses the reaction between malate and NAD(+) and produces NADH, which converts hexacyanoferrate(III) into hexacyanoferrate(II) in the presence of the DI, Amperometric measurements with pure graphite electrodes in a fully automated flow injection manifold were used to monitor the concentration of hexacyanoferrate(II) at +0.3 V versus an Ag/AgCl reference electrode, The electrochemical behaviour of hexacyanoferrate(III), 2,6-dichlorophenolindophenol and p-benzoquinone was tested with cyclic voltammetry. Parameters such as working and immobilization pH, flow rate, sample size, temperature and NAD(+) and hexacyanoferrate(III) concentrations were investigated, The interference of various ions, amino acids and organic acids present in real samples was also studied, The calibration graph was linear for the range 2 x 10(-5)-4 x 10(-4) mol l(-1) malate, The reactors remained active for a period of more than 3 months under specified storage conditions, The maximum sample throughput was 30 h(-1) and the relative standard deviation of the method was better than 1.5% (n = 5), The mean relative error was 4% for fruits-and 2% for vegetables, The accuracy of the proposed method was tested by comparison of the results with those obtained by a reference method. Good correlation was attained, Recovery experiments showed results between 95 and 108%.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 27 条
[11]  
GARDNER WH, 1972, HDB FOOD ADDITIVES, P239
[12]   A FLUORIMETRIC ENZYMIC METHOD FOR ASSAY OF MIXTURES OF ORGANIC ACIDS [J].
GUILBAUL.GG ;
SADAR, SH ;
MCQUEEN, R .
ANALYTICA CHIMICA ACTA, 1969, 45 (01) :1-&
[13]  
Gutmann I, 1974, METHOD ENZYMAT AN, P1585
[14]  
HORWITZ W, 1975, OFFICIAL METHODS ANA, P406
[15]   COMPARATIVE KINETIC STUDY FOR RATE CONSTANT DETERMINATION OF REACTION OF ASCORBIC-ACID WITH 2,6-DICHLOROPHENOLINDOPHENOL [J].
KARAYANNIS, MI .
TALANTA, 1976, 23 (01) :27-30
[16]   A bienzyme electrode probe for malate [J].
Messia, MC ;
Compagnone, D ;
Esti, M ;
Palleschi, G .
ANALYTICAL CHEMISTRY, 1996, 68 (02) :360-365
[17]  
Mollering H., 1974, METHOD ENZYMAT AN, V3, P1589
[18]   SIMULTANEOUS USE OF DEHYDROGENASES AND HEXACYANOFERRATE(III) ION IN ELECTROCHEMICAL BIOSENSORS FOR L-LACTATE, D-LACTATE AND L-GLUTAMATE IONS [J].
MONTAGNE, M ;
DURLIAT, H ;
COMTAT, M .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :25-33
[19]   UPGRADE OF A SEMIAUTOMATIC FLOW-INJECTION ANALYSIS SYSTEM TO A FULLY-AUTOMATIC ONE BY MEANS OF A RESIDENT PROGRAM [J].
PRODROMIDIS, MI ;
TSIBIRIS, AB ;
KARAYANNIS, MI .
JOURNAL OF AUTOMATIC CHEMISTRY, 1995, 17 (05) :187-190
[20]  
PRODROMIDIS MI, IN PRESS TALANTA