Diffusion tensor imaging with cerebrospinal fluid suppression and signal-to-noise preservation using acquisition combining fluid-attenuated inversion recovery and conventional imaging: Comparison of fiber tracking

被引:13
作者
Cheng, Yen-Wei [2 ]
Chung, Hsiao-Wen [2 ,3 ]
Chen, Cheng-Yu [3 ]
Chou, Ming-Chung [1 ]
机构
[1] Kaohsiung Med Univ, Dept Med Imaging & Radiol Sci, Kaohsiung 80708, Taiwan
[2] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
[3] Tri Serv Gen Hosp, Dept Radiol, Taipei, Taiwan
关键词
Diffusion tensor imaging; Fiber tractography; Cerebrospinal fluid; Partial volume effects; Fluid-attenuated inversion recovery; HUMAN BRAIN CONNECTIVITY; ACUTE ISCHEMIC-STROKE; WHITE-MATTER; TRACTOGRAPHY; MRI; ANISOTROPY; FLAIR; DTI; CONTAMINATION; PARALLEL;
D O I
10.1016/j.ejrad.2009.12.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To propose an acquisition scheme suitable for fiber tractography without cerebrospinal fluid contamination while retaining high signal-to-noise ratio. Materials and methods: Diffusion tensor imaging (DTI) data at b = 0 and 1000s/mm(2) were acquired using conventional spin-echo echo-planar imaging (TR/TE = 4000/69, NEX = 4, scan time 2: 14) plus one additional fluid-attenuated inversion recovery (FLAIR) b = 0 set obtained at TI = 2200, TR = 6000, and NEX = 6 (scan time 1: 36). The FLAIR images were intensity-adjusted to match the conventional b = 0 images according to the white matter signals. Five healthy adults were scanned, with tractography performed from conventional b = 1000 and FLAIR b = 0 images using the EZ-tracing algorithm. Total traced volumes were statistically compared among conventional DTI, FLAIR DTI, and the "combined DTI" methods at three different slice thicknesses. The fiber consistency index was derived for five repeated scans to assess possible false tracts. Results: Whole-brain traced volumes from FLAIR DTI and combined DTI were 9.7% (p < 0.001) and 17.0% (p < 0.0001) greater than from conventional DTI, respectively (paired Student t-test). Fiber consistency was similar for all three acquisition techniques (p > 0.2), suggesting insignificant difference in false tracking. Compared with conventional DTI, the increase in total traced volume for FLAIR DTI diminished with decreasing slice thickness, whereas the tractography advantage for combined DTI became increasingly prominent at thinner slices. Conclusions: The combined DTI technique is capable of improving tractography with higher signal-to-noise ratio at shorter scan time than FLAIR DTI. Its superiority at thin-slice acquisitions makes it particularly suitable for high-resolution clinical applications. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 21 条
[1]  
Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
[2]  
2-O
[3]   Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review [J].
Basser, PJ ;
Jones, DK .
NMR IN BIOMEDICINE, 2002, 15 (7-8) :456-467
[4]   Acute ischemic stroke:: Accuracy of diffusion-weighted MR imaging -: Effects of b value and cerebrospinal fluid suppression [J].
Chen, PE ;
Simon, JE ;
Hill, MD ;
Sohn, CH ;
Dickhoff, P ;
Morrish, WF ;
Sevick, RJ ;
Frayne, R .
RADIOLOGY, 2006, 238 (01) :232-239
[5]  
Chou MC, 2005, AM J NEURORADIOL, V26, P591
[6]   Tensor deflection (TEND) tractography with adaptive subvoxel stepping [J].
Chou, Ming-Chung ;
Wu, Ming-Long ;
Chen, Cheng-Yu ;
Wang, Chao-Ying ;
Huang, Teng-Yi ;
Liu, Yi-Jui ;
Juan, Chun-Jung ;
Chung, Hsiao-Wen .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (02) :451-458
[7]   PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: Application to high-resolution diffusion tensor imaging [J].
Chuang, Tzu-Chao ;
Huang, Teng-Yi ;
Lin, Fa-Hsuan ;
Wang, Fu-Nien ;
Juan, Chun-Jung ;
Chung, Hsiao-Wen ;
Chen, Cheng-Yu ;
Kwong, Kenneth K. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) :1352-1358
[8]  
Concha L, 2005, AM J NEURORADIOL, V26, P2267
[9]   DTI mapping of human brain connectivity: statistical fibre tracking and virtual dissection [J].
Hagmann, P ;
Thiran, JP ;
Jonasson, L ;
Vandergheynst, P ;
Clarke, S ;
Maeder, P ;
Meuli, R .
NEUROIMAGE, 2003, 19 (03) :545-554
[10]   Comparison of diffusion anisotropy measurements in combination with the flair-technique [J].
Hirsch, JG ;
Bock, M ;
Essig, M ;
Schad, LR .
MAGNETIC RESONANCE IMAGING, 1999, 17 (05) :705-716