PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: Application to high-resolution diffusion tensor imaging

被引:37
作者
Chuang, Tzu-Chao
Huang, Teng-Yi
Lin, Fa-Hsuan
Wang, Fu-Nien
Juan, Chun-Jung
Chung, Hsiao-Wen [1 ]
Chen, Cheng-Yu
Kwong, Kenneth K.
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
[3] MIT, Massachusetts Gen Hosp, HMS A Martinos Ctr Biomed Imaging, Charlestown, MA USA
[4] Tri Serv Gen Hosp, Dept Radiol, Taipei, Taiwan
[5] Natl Defense Med Ctr, Taipei, Taiwan
关键词
PROPELLER imaging; parallel imaging; high-resolution diffusion image; PROPELLER-EPI; geometric distortions;
D O I
10.1002/mrm.21064
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A technique integrating multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and parallel imaging is presented for diffusion echo-planar imaging (EPI) at high spatial resolution. The method combines the advantages of parallel imaging to achieve accelerated sampling along the phase-encoding direction, and PROPELLER acquisition to further decrease the echo train length (ETL) in EPI. With an eight-element circularly symmetric RF coil, a parallel acceleration factor of 4 was applied such that, when combined with PROPELLER acquisition, a reduction of geometric distortions by a factor substantially greater than 4 was achieved. The resulting phantom and human brain images acquired with a 256 x 256 matrix and an ETL of only 16 were visually identical in shape to those acquired using the fast spin-echo (FSE) technique, even without field-map corrections. It is concluded that parallel PROPELLER-EPI is an effective technique that can substantially reduce susceptibility-induced geometric distortions at high field strength.
引用
收藏
页码:1352 / 1358
页数:7
相关论文
共 27 条
[1]   k-space undersampling in PROPELLER imaging [J].
Arfanakis, K ;
Tamhane, AA ;
Pipe, JG ;
Anastasio, MA .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :675-683
[2]   Diffusion tensor imaging using single-shot SENSE-EPI [J].
Bammer, R ;
Auer, M ;
Keeling, SL ;
Augustin, M ;
Stables, LA ;
Prokesch, RW ;
Stollberger, R ;
Moseley, ME ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :128-136
[3]  
Bourland JD, 1999, NEUROIMAG CLIN N AM, V9, P363
[4]   PHYSIOLOGICAL-EFFECTS OF FAST OSCILLATING MAGNETIC-FIELD GRADIENTS [J].
BUDINGER, TF ;
FISCHER, H ;
HENTSCHEL, D ;
REINFELDER, HE ;
SCHMITT, F .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (06) :909-914
[5]  
Chen NK, 2001, MAGNET RESON MED, V45, P525, DOI 10.1002/1522-2594(200103)45:3<525::AID-MRM1070>3.0.CO
[6]  
2-S
[7]   Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging [J].
Forbes, KP ;
Pipe, JG ;
Karis, JP ;
Heiserman, JE .
RADIOLOGY, 2002, 225 (02) :551-555
[8]   High-resolution isotropic 3D diffusion tensor Imaging of the human brain [J].
Golay, X ;
Jiang, H ;
van Zijl, PCM ;
Mori, S .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :837-843
[9]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[10]   SENSE-DTI at 3 T [J].
Jaermann, T ;
Crelier, G ;
Pruessmann, KP ;
Golay, X ;
Netsch, T ;
van Muiswinkel, AMC ;
Mori, S ;
van Zijl, PCM ;
Valavanis, A ;
Kollias, S ;
Boesiger, P .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) :230-236