Organ dose conversion coefficients for 0.1-10 MeV electrons calculated for the VIP-MAN tomographic model

被引:30
作者
Chao, TC
Bozkurt, A
Xu, XG
机构
[1] Rensselaer Polytech Inst, Nucl Engn Program, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Engn Phys Program, Troy, NY 12180 USA
[3] Harran Univ, Fac Arts & Sci, Dept Phys, TR-63200 Sanliurfa, Turkey
来源
HEALTH PHYSICS | 2001年 / 81卷 / 02期
关键词
phantom; electrons; Monte Carlo; dose assessment;
D O I
10.1097/00004032-200108000-00012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A whole-body tomographic model, called VIP-Man, was recently developed at Rensselaer Polytechnic Institute from the high-resolution color photographic images of the National Library of Medicine's Visible Human Project. An EGS4-based Monte Carlo user code, named EGS4-VLSI, was developed to efficiently transport electrons using the large image data set for VIP-Man. VIP-Man has been used to calculate doses for neutrons and photons. This paper presents a new set of fluence-to-absorbed-dose conversion coefficients for monoenergetic electron beams between 100 keV and 10 MeV for VIP-Man. Irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational, and isotropic source geometries, Comparisons between organ doses from VIP-Man, which is taller and heavier than the Reference Man, and existing data from mathematical models show significant discrepancies. It appears that even slight differences between body models can cause dramatic dosimetric deviations for low penetrating electron irradiation. This suggests that a single standard body model may poorly represent a large population and may not be acceptable for electron dosimetry.
引用
收藏
页码:203 / 214
页数:12
相关论文
共 38 条
[21]   A realistic anthropomorphic phantom for calculating organ doses arising from external photon irradiation [J].
Jones, DG .
RADIATION PROTECTION DOSIMETRY, 1997, 72 (01) :21-29
[22]   Effective doses and organ doses per unit fluence calculated for monoenergetic 0.1 Mev to 100 MeV electrons by the MIRD-5 phantom [J].
Katagiri, M ;
Hikoji, M ;
Kitaichi, M ;
Sawamura, S ;
Aoki, Y .
RADIATION PROTECTION DOSIMETRY, 2000, 90 (04) :393-401
[23]  
KRAMER R, 1982, S885 GSF NAT RES CTR
[24]   Accurate characterization of Monte Carlo calculated electron beams for radiotherapy [J].
Ma, CM ;
Faddegon, BA ;
Rogers, DWO ;
Mackie, TR .
MEDICAL PHYSICS, 1997, 24 (03) :401-416
[25]  
Marsaglia G., 1991, The Annals of Applied Probability, V1, P462, DOI [DOI 10.1214/A0AP/1177005878, 10.1214/aoap/1177005878]
[26]   Comprehensive Analysis of mRNA Methylation Reveals Enrichment in 3′ UTRs and near Stop Codons [J].
Meyer, Kate D. ;
Saletore, Yogesh ;
Zumbo, Paul ;
Elemento, Olivier ;
Mason, Christopher E. ;
Jaffrey, Samie R. .
CELL, 2012, 149 (07) :1635-1646
[27]  
MOLIERE GZ, 1947, Z NATURFORSCH A, V2
[28]  
NELSON W, 1985, SLAC265UC32
[29]   Voxel anthropomorphic models as a tool for internal dosimetry [J].
Petoussi-Henss, N ;
Zankl, M .
RADIATION PROTECTION DOSIMETRY, 1998, 79 (1-4) :415-418
[30]  
ROGERS DW, 1989, MONTE CARLO TRANSPOR