Analysis of large-volume DNA markers and polymerase chain reaction products by capillary electrophoresis in the presence of electroosmotic flow

被引:29
作者
Tseng, WL [1 ]
Hsieh, MM [1 ]
Wang, SJ [1 ]
Huang, CC [1 ]
Lin, YC [1 ]
Chang, PL [1 ]
Chang, HT [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem, Taipei 106, Taiwan
关键词
sample stacking; DNA; poly(ethylene oxide);
D O I
10.1016/S0021-9673(01)01122-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have demonstrated on-line concentration and separation of DNA in the presence of electroosmotic flow (EOF) using poly(ethylene oxide) (PEO) solutions. After injecting large-volumes DNA samples, PEO solutions entered a capillary filled with 400 mM Tris-borate (TB) buffers by EOF and acted as sieving matrices. DNA fragments stacked between the sample zone and PEO solutions. Because sample matrixes affected PEO adsorption on the capillary wall, leading to changes in EOF, migration time, concentration, and resolving power varied with the injection length. When injecting Phi X174 RF DNA-HaeIII digest prepared in 5 mM Tris-HCl buffer, pH 7.0, at 250 V/cm, peak height increased linearly as a function of injection volume up to 0.9 mul(injection time 150 s). The sensitivity improvement was 100-fold compare to that injected at 25 V/cm for 10 s (0.006 mu1). When injecting 1.54 mul of GeneScan 1000 ROX, the sensitivity improvement was 265-fold. The sensitivity improvement was 40-fold when injecting 0.17 mul DNA sample containing pBR 322/HaeIII, pBR 328/Bg/I, and pBR 328/HinfI digests prepared in phosphate-buffered saline. This method allows the analysis of polymerase, chain reaction (PCR) products amplified after 17 cycles when injecting 0.32 mul (at 30 cm height for 300 s). The total analysis time was shorter (91.6 min) than that (119.6 min) obtained from injecting PCR products after 32 cycles for 10 s. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:179 / 190
页数:12
相关论文
共 50 条
[1]   Analysis of oligonucleotides by on-column transient capillary isotachophoresis and capillary electrophoresis in poly(ethylene glycol)-filled columns [J].
Auriola, S ;
Jaaskelainen, I ;
Regina, M ;
Urtti, A .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3907-3911
[2]   Preconcentration and separation of antisense oligonucleotides by on-column isotachophoresis and capillary electrophoresis in polymer-filled capillaries [J].
Barmé, I ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ELECTROPHORESIS, 1998, 19 (8-9) :1445-1451
[3]   The effects of polymer properties on DNA separations by capillary electrophoresis in uncross-linked polymer solutions [J].
Barron, AE ;
Sunada, WM ;
Blanch, HW .
ELECTROPHORESIS, 1996, 17 (04) :744-757
[4]  
Beckers JL, 2000, ELECTROPHORESIS, V21, P2747, DOI 10.1002/1522-2683(20000801)21:14<2747::AID-ELPS2747>3.0.CO
[5]  
2-Z
[6]   Direct quantification of polymerase chain reaction fragments using field-amplified sample injection in capillary zone electrophoresis for gene dosage estimation [J].
Beckmann, A ;
Gebhardt, F ;
Brandt, BH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 710 (1-2) :75-80
[7]   STIFF (DNA) AND FLEXIBLE (NAPSS) POLYELECTROLYTE CHAIN EXPANSION AT VERY-LOW SALT CONCENTRATION [J].
BOROCHOV, N ;
EISENBERG, H .
MACROMOLECULES, 1994, 27 (06) :1440-1445
[8]   QUANTITATION OF POLYMERASE CHAIN-REACTION PRODUCTS BY CAPILLARY ELECTROPHORESIS USING LASER FLUORESCENCE [J].
BUTLER, JM ;
MCCORD, BR ;
JUNG, JM ;
WILSON, MR ;
BUDOWLE, B ;
ALLEN, RO .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 658 (02) :271-280
[9]   Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions [J].
Carrilho, E ;
RuizMartinez, MC ;
Berka, J ;
Smirnov, I ;
Goetzinger, W ;
Miller, AW ;
Brady, D ;
Karger, BL .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3305-3313
[10]   OPTIMIZATION OF SELECTIVITY IN CAPILLARY ZONE ELECTROPHORESIS VIA DYNAMIC PH GRADIENT AND DYNAMIC FLOW GRADIENT [J].
CHANG, HT ;
YEUNG, ES .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :65-72