Modulation of bone ingrowth of rabbit femur titanium implants by in vivo axial micromechanical loading

被引:25
作者
Clark, PA
Rodriguez, A
Sumner, DR
Hussain, MA
Mao, JJ
机构
[1] Univ Illinois, Dept Bioengn, Tissue Engn Lab, Chicago, IL 60612 USA
[2] Univ Illinois, Dept Orthodont, Chicago, IL 60612 USA
[3] Rush Univ, Dept Anat & Cell Biol, Chicago, IL 60612 USA
关键词
orthopedics; mechanobiology; mechanotransduction; bone histomorphometry;
D O I
10.1152/japplphysiol.01080.2004
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Titanium implants commonly used in orthopedics and dentistry integrate into host bone by a complex and coordinated process. Despite increasingly well illustrated molecular healing processes, mechanical modulation of implant bone ingrowth is poorly understood. The objective of the present study was to determine whether micromechanical forces applied axially to titanium implants modulate bone ingrowth surrounding intraosseous titanium implants. We hypothesized that small doses of micromechanical forces delivered daily to the bone-implant interface enhance implant bone ingrowth. Small titanium implants were placed transcortically in the lateral aspect of the proximal femur in 15 New Zealand White rabbits under general anesthesia and allowed to integrate with the surrounding bone for 6 wk. Micromechanical forces at 200 mN and 1 Hz were delivered axially to the right femur implants for 10 min/day over 12 consecutive days, whereas the left femur implants served as controls. The average bone volume 1 mm from mechanically loaded implants ( n = 15) was 73 +/- 12%, which was significantly greater than the average bone volume ( 52 +/- 21%) of the contralateral controls ( n = 15) ( P < 0.01). The average number of osteoblast-like cells per endocortical bone surface was 55 +/- 8 cells/mm(2) for mechanically loaded implants, which was significantly greater than the contralateral controls ( 35 +/- 6 cells/mm(2)) ( P < 0.01). Dynamic histomorphometry showed a significant increase in mineral apposition rate and bone-formation rate of mechanically stressed implants (3.8 +/- 1.2 mu m/day and 2.4 +/- 1.0 mu m(3) center dot mu m(-2) center dot day(-1), respectively) than contralateral controls (2.2 +/- 0.92 mu m/day and 1.2 +/- 0.60 mu m(3) center dot mu m(-2) center dot day(-1), respectively; P < 0.01). Collectively, these data suggest that micromechanical forces delivered axially on intraosseous titanium implants may have anabolic effects on implant bone ingrowth.
引用
收藏
页码:1922 / 1929
页数:8
相关论文
共 75 条
[11]  
Carter DR, 1998, CLIN ORTHOP RELAT R, pS41
[12]   Implant design and interface force transfer - A photoelastic and strain-gauge analysis [J].
Cehreli, M ;
Duyck, J ;
De Cooman, M ;
Puers, R ;
Naert, I .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) :249-257
[13]   Expression of matrix metalloproteinase genes in the rat intramembranous bone during postnatal growth and upon mechanical stresses [J].
Collins, JM ;
Ramamoorthy, K ;
Da Silveira, A ;
Patston, P ;
Mao, JJ .
JOURNAL OF BIOMECHANICS, 2005, 38 (03) :485-492
[14]  
Cook S D, 1992, J Oral Implantol, V18, P359
[15]   Physiological strains induce differentiation in human osteoblasts cultured on orthopaedic biomaterial [J].
Di Palma, F ;
Douet, M ;
Boachon, C ;
Guignandon, A ;
Peyroche, S ;
Forest, B ;
Alexandre, C ;
Chamson, A ;
Rattner, A .
BIOMATERIALS, 2003, 24 (18) :3139-3151
[16]   Single tooth bite forces in healthy young adults [J].
Ferrario, VF ;
Sforza, C ;
Serrao, G ;
Dellavia, C ;
Tartaglia, GM .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (01) :18-22
[17]   Osseointegration on metallic implant surfaces: Effects of microgeometry and growth factor treatment [J].
Frenkel, SR ;
Simon, J ;
Alexander, H ;
Dennis, M ;
Ricci, JL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (06) :706-713
[18]   Autologous osteoblasts enhance osseointegration of porous titanium implants [J].
Frosch, KH ;
Sondergeld, I ;
Dresing, K ;
Rudy, T ;
Lohmann, CH ;
Rabba, J ;
Schild, D ;
Breme, J ;
Stuermer, KM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (02) :213-223
[19]   BONE MASS AND THE MECHANOSTAT - A PROPOSAL [J].
FROST, HM .
ANATOMICAL RECORD, 1987, 219 (01) :1-9
[20]  
Frost HM, 1996, ANAT RECORD, V244, P139, DOI 10.1002/(SICI)1097-0185(199602)244:2<139::AID-AR1>3.0.CO