Sensor film for Vitamin C determination based on absorption properties of polyaniline

被引:44
作者
Andreu, Y [1 ]
de Marcos, S [1 ]
Castillo, JR [1 ]
Galbán, J [1 ]
机构
[1] Univ Zaragoza, Fac Sci, Analyt Chem Dept, Analyt Spectroscopy & Sensors Grp, Zaragoza 50009, Spain
关键词
optical sensor film; vitamin C; polyaniline; redox;
D O I
10.1016/j.talanta.2004.08.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method based on the absorption changes of chemically polymerised polyaniline at 700 rum is proposed for the determination of Vitamin C. Vitamin C produces a polyanifine film reduction, originating changes in its absorbance proportional to the Vitamin C concentration. The optimum reaction conditions and the analytical characteristics have been studied. The linear response of the method ranged from 0.10 to 1.0 mg l(-1) for a 6 min reaction time and from 1.0 to 8.0 mg l(-1) for a 2 min reaction time. Reproducibility, expressed as the coefficient of variation, was 0.8% (6 min reaction time) and 2.3% (2 min reaction time) (n = 10). The method has been applied to Vitamin C determination in pharmaceutical preparations and commercial fruit juices. The results were compared with those obtained by the 2,6-dichlorophenolindophenol titration method (the AOAC Official Method) and no systematic errors were observed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1045 / 1051
页数:7
相关论文
共 25 条
[1]   Optical ozone detection by use of polyaniline film [J].
Ando, M ;
Swart, C ;
Pringsheim, E ;
Mirsky, VM ;
Wolfbeis, OS .
SOLID STATE IONICS, 2002, 152 :819-822
[2]   Food analyses:: a new calorimetric method for ascorbic acid (vitamin C) determination [J].
Antonelli, ML ;
D'Ascenzo, G ;
Laganà, A ;
Pusceddu, P .
TALANTA, 2002, 58 (05) :961-967
[3]   Reagentless system for sulphite determination based on polyaniline [J].
de Marcos, S ;
Alcubierre, N ;
Galbán, J ;
Castillo, JR .
ANALYTICA CHIMICA ACTA, 2004, 502 (01) :7-13
[4]   Kinetic-spectrophotometric determination of ascorbic acid by inhibition of the hydrochloric acid-bromate reaction [J].
Ensafi, AA ;
Rezaei, B ;
Movahedinia, H .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (12) :2589-2594
[5]   Conducting polymers prepared by oxidative polymerization: Polyaniline [J].
Gospodinova, N ;
Terlemezyan, L .
PROGRESS IN POLYMER SCIENCE, 1998, 23 (08) :1443-1484
[6]   Polyaniline based optical pH sensor [J].
Grummt, UW ;
Pron, A ;
Zagorska, M ;
Lefrant, S .
ANALYTICA CHIMICA ACTA, 1997, 357 (03) :253-259
[7]  
HERRERA E, 1985, BIOQUIMICA
[8]   Routine high-performance liquid chromatographic determination of ascorbic acid in foods using L-methionine for the pre-analysis sample stabilization [J].
Iwase, H .
TALANTA, 2003, 60 (05) :1011-1021
[9]   An improved optical pH sensor based on polyaniline [J].
Jin, Z ;
Su, YX ;
Duan, YX .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 71 (1-2) :118-122
[10]   Development of a polyaniline-based optical ammonia sensor [J].
Jin, Z ;
Su, YX ;
Duan, YX .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (01) :75-79