Variation in pacing impedance: Impact of implant site and measurement method

被引:8
作者
Anderson, Sara E.
Skadsberg, Nicholas D.
Laske, Timothy G.
Benditt, David G.
Iaizzo, Paul A.
机构
[1] Univ Minnesota, Dept Surg, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN USA
[3] Medtronic Inc, Minneapolis, MN USA
[4] Univ Minnesota, Sch Med, Dept Med, Cardiac Arrhythmia Ctr,Cardiovasc Div, Minneapolis, MN 55455 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2007年 / 30卷 / 09期
关键词
impedance; pacing; endocardium; atrium; ventricle; LEAD IMPEDANCE; SYSTEM ANALYZERS; VARIABILITY;
D O I
10.1111/j.1540-8159.2007.00816.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Variations in pacing impedance may be observed during implantation of various active fixation pacing leads. However, these variations can be influenced by the nature of the fixation, the implant site, or the measurement method. Here we describe implant dynamics for a 4.1F, catheter-delivered pacemaker lead. Methods: Endocardial active fixation leads were implanted under direct intracardiac visualization in two right atrial sites and three right ventricular sites in isolated swine (n = 6) and human (n = 4) hearts. Impedance measurements were recorded at each site employing three different measurement techniques-Pacing System Analyzer (PSA) 5311, PSA 2090, and the Impedance Tone Box (Medtronic, Inc., Minneapolis, MN, USA)-with four different degrees of lead fixation: helix touching, one turn fixed (1 TF), two turns fixed (2 TF), and overtorqued. Results: Pacing impedances increased from touching to 1 TF to 2 TF at all implant sites in both swine and human hearts. Overtorquing applied to leads was associated with visible distortion at the endocardial tissue-lead interface in at least 60% of swine (18 of 30 implants) and human hearts (nine of 14 implants). Impedance values in the right atrial high septum were significantly larger than in any other implant site (P < 0.05). The three measurement methods did not yield significantly different impedance measurements. Conclusions: Variations in measured impedances were associated with the nature of implant fixation at all sites in both swine and human hearts.
引用
收藏
页码:1076 / 1082
页数:7
相关论文
共 17 条
[1]   SOURCES OF ERROR IN THE DETERMINATION OF OUTPUT VOLTAGE OF PULSE GENERATORS BY PACEMAKER SYSTEM ANALYZERS [J].
BAROLD, SS ;
ROEHRICH, DR ;
FALKOFF, MD ;
ONG, LS ;
HEINLE, RA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1980, 3 (05) :585-596
[2]   DIRECT AND TELEMETERED LEAD IMPEDANCE [J].
BENZUR, UM ;
PLATT, SB ;
GROSS, JN ;
KIM, JS ;
DELEON, J ;
GUGUCHEV, P ;
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11) :2004-2007
[3]   INTRAOPERATIVE PACEMAKER ELECTRICAL TESTING [J].
CALVIN, JW .
ANNALS OF THORACIC SURGERY, 1978, 26 (02) :165-176
[4]   Isolated four-chamber working swine heart model [J].
Chinchoy, E ;
Soule, CL ;
Houlton, AJ ;
Gallagher, WJ ;
Hjelle, MA ;
Laske, TG ;
Morissette, J ;
Iaizzo, PA .
ANNALS OF THORACIC SURGERY, 2000, 70 (05) :1607-1614
[5]   Pacing impedance variability in tined steroid eluting leads [J].
Danilovic, D ;
Ohm, OJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (07) :1356-1363
[6]  
Duffin E, 1986, CLIN PROG ELECTROPHY, V4, P449
[7]   Automatic impedance monitoring and patient alert feature in implantable cardioverter defibrillators: Being alert for the unexpected! [J].
Duru, F ;
Luechinger, R ;
Scharf, C ;
Brunckhorst, C .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (04) :444-448
[8]   In vitro studies of human hearts [J].
Hill, AJ ;
Laske, TG ;
Coles, JA ;
Sigg, DC ;
Skadsberg, ND ;
Vincent, SA ;
Soule, CL ;
Gallagher, WJ ;
Iaizzo, PA .
ANNALS OF THORACIC SURGERY, 2005, 79 (01) :168-177
[9]   IMPEDANCE TO DEFIBRILLATION COUNTERSHOCK - DOES AN OPTIMAL IMPEDANCE EXIST [J].
KENKNIGHT, BH ;
EYUBOGLU, BM ;
IDEKER, RE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (11) :2068-2087
[10]   High pacing impedances: Are you overtorquing your leads? [J].
Laske, TG ;
Vieau, SA ;
Skadsberg, ND ;
Iaizzo, PA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (09) :883-891