Detection of Staphylococcus enterotoxin B at picogram levels using piezoelectric-excited millimeter-sized cantilever sensors

被引:52
作者
Campbell, Gossett A.
Medina, Marjorie B.
Mutharasan, Raj
机构
[1] Drexel Univ, Dept Chem & Biochem Engn, Philadelphia, PA 19104 USA
[2] USDA, Agr Res Serv, Eastern Reg Res Ctr, Wyndmoor, PA 19038 USA
关键词
immumosensor; mass change; flow cell; resonance frequency;
D O I
10.1016/j.snb.2007.03.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a highly sensitive and rapid method for the detection of Staphylococcus aureus enterotoxin B (SEB) at picogram levels using a piezoelectric -excited millimeter- sized cantilever (PEMC) sensor. Affinity purified polyclonal antibody to Staphylococcal enterotoxin B (anti-SEB) was immobilized on the aminated cantilever glass surface, followed by exposure of SEB containing samples flowing at a rate of 1 mL/min. The binding of SEB was measured by monitoring the sensor's fundamental resonance frequency. The fundamental frequencies in air and under liquid immersion were 17.50 +/- 0.01 kHz and 10.37 +/- 0.01 kHz, respectively. Binding of SEB to the sensor surface resulted in an exponential decrease of the resonance frequency and reached a steady state frequency change of 31 +/- 1 Hz (n = 2) and 208 +/- 1 Hz (n = 2) corresponding to SEB concentrations of 50 pg/mL and 12.5 ng/mL. respectively. In each experiment, the bound SEB was released by a pH 2.0 HCI/PBS solution and the sensor response was nearly identical to the frequency change caused by attachment. Full antibody surface regeneration was obtained after the release by rinsing, the sensor with PBS pH 7.4. We report the detection limit of PEMC sensors to SEB is between 12.5 pg/mL and 50 pg/mL. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:354 / 360
页数:7
相关论文
共 36 条
[1]   Ganglioside-liposome immunoassay for the ultrasensitive detection of cholera toxin [J].
Ahn-Yoon, S ;
DeCory, TR ;
Baeumner, AJ ;
Durst, RA .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2256-2261
[2]   A rapid and sensitive magnetic bead-based immunoassay for the detection of staphylococcal enterotoxin B for high-through put screening [J].
Alefantis, T ;
Grewal, P ;
Ashton, J ;
Khan, AS ;
Valdes, JJ ;
Del Vecchio, VG .
MOLECULAR AND CELLULAR PROBES, 2004, 18 (06) :379-382
[3]  
ALOISI RM, 1981, AM J MED TECHNOL, V47, P913
[4]   Transient capacitance measurements of the transport and trap states distributions in a conjugated polymer [J].
Campbell, A. J. ;
Bradley, D. D. C. ;
Werner, E. ;
Bruetting, W. .
ORGANIC ELECTRONICS, 2000, 1 (01) :21-26
[5]   Use of piezoelectric-excited millimeter-sized cantilever sensors to measure albumin interaction with self-assembled monolayers of alkanethiols having different functional headgroups [J].
Campbell, GA ;
Mutharasan, R .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2328-2334
[6]   Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors detect Bacillus anthracis at 300 spores/mL [J].
Campbell, GA ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (09) :1684-1692
[7]   Monitoring of the self-assembled monolayer of 1-hexadecanethiol on a gold surface at nanomolar concentration using a piezo-excited millimeter-sized cantilever sensor [J].
Campbell, GA ;
Mutharasan, R .
LANGMUIR, 2005, 21 (25) :11568-11573
[8]   Detection and quantification of proteins using self-excited PZT-glass millimeter-sized cantilever [J].
Campbell, GA ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (04) :597-607
[9]   Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers [J].
Campbell, GA ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (03) :462-473
[10]   Detection of Bacillus anthracis spores and a model protein using PEMC sensors in a flow cell at 1 mL/min [J].
Campbell, Gossett A. ;
Mutharasan, Raj .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (01) :78-85