Detection and quantification of proteins using self-excited PZT-glass millimeter-sized cantilever

被引:49
作者
Campbell, GA [1 ]
Mutharasan, R [1 ]
机构
[1] Drexel Univ, Dept Chem Engn, Philadelphia, PA 19104 USA
关键词
resonance; protein; interaction; binding kinetics; sensitivity;
D O I
10.1016/j.bios.2004.12.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A composite self-excited PZT-glass cantilever (4 mm in length and 2 mm wide) was fabricated and used to measure the binding and unbinding of model proteins. A key feature of the cantilever is that its resonant frequency is dependent on its mass. The fabricated cantilever has mass change sensitivity in liquid of 7.2 x 10(-11) g/Hz. Resonant frequency change was measured as protein reacted or bound with the sensing glass cantilever surface. Protein concentrations, 0.1 and 1.0 mg/mL, which resulted in nanograrn mass change were successfully detected. The mass change sensitivity gave a total mass change of 54 +/- 0.45 ng for the binding of anti-rabbit IgG (biotin conjugated) to rabbit IgG immobilized cantilever and the subsequent binding of captavidin. The unbinding of anti-rabbit IgG and captavidin gave a total mass change of 54 +/- 1.70 ng. Fluorescence based assays showed the combined mass of both proteins in the released samples was 54 +/- 2.24 ng. The binding kinetics of the model proteins is modeled as first order. The initial binding rate constant of anti-rabbit IgG to rabbit I-G was 1.36 +/- 0.02 (min (mg/mL))The initial binding rate constant of captavidin to biotinylated anti-rabbit IgG was (2.57 x 10(-1)) 0.003 (min (mg/mL))(-1). The significance of the results we report here is that millimeter-sized PZT-actuated glass cantilevers have the sensitivity to measure in real-time protein-protein binding, and the binding rate constant. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:597 / 607
页数:11
相关论文
共 33 条
[1]   Development of nanomechanical biosensors for detection of the pesticide DDT [J].
Alvarez, M ;
Calle, A ;
Tamayo, J ;
Lechuga, LM ;
Abad, A ;
Montoya, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :649-653
[2]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[3]   PROTEIN MEASUREMENT USING BICINCHONINIC ACID - ELIMINATION OF INTERFERING SUBSTANCES [J].
BROWN, RE ;
JARVIS, KL ;
HYLAND, KJ .
ANALYTICAL BIOCHEMISTRY, 1989, 180 (01) :136-139
[4]   Human growth hormone adsorption kinetics and conformation on self-assembled monolayers [J].
Buijs, J ;
Britt, DW ;
Hlady, V .
LANGMUIR, 1998, 14 (02) :335-341
[5]   Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers [J].
Campbell, GA ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (03) :462-473
[6]  
CASS T, 1998, IMMOBILIZED BIOMOLEC, P4
[7]  
Chuang H. Y. K., 1987, BLOOD COMPATIBILITY, V1, P87
[8]   Detection of non-specific protein adsorption at artificial surfaces by the use of acoustic plate mode sensors [J].
Dahint, R ;
Seigel, RR ;
Harder, P ;
Grunze, M ;
Josse, F .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 36 (1-3) :497-505
[9]   Eigenfrequencies of a rectangular atomic force microscope cantilever in a medium [J].
Elmer, FJ ;
Dreier, M .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (12) :7709-7714
[10]   Effect of hydrogel matrix on binding kinetics of protein-protein interactions on sensor surface [J].
Fong, CC ;
Wong, MS ;
Fong, WF ;
Yang, MS .
ANALYTICA CHIMICA ACTA, 2002, 456 (02) :201-208