Blood flow in stented arteries: A parametric comparison of strut design patterns in three dimensions

被引:61
作者
He, Y
Duraiswamy, N
Frank, AO
Moore, JE
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15261 USA
[3] Florida Int Univ, Dept Biomed Engn, Miami, FL 33199 USA
[4] Appl Res Associates Inc, Ft Worth, TX 76109 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 04期
关键词
D O I
10.1115/1.1934122
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background: Restenosis after stent implantation varies with stent design. Alterations in secondary flow patterns and wall shear stress (WSS) can modulate intimal hyperplasia via their effects on platelet and inflammatory cell transport toward the wall, as well as direct effects on the endothelium. Method of Approach: Detailed flow characteristics were compared by estimating the WSS in the near-strut region of realistic stent designs using three-dimensional computational fluid dynamics (CFD), under pulsatile high and low flow conditions. The stent geometry employed was characterized by three geometric parameters (axial strut pitch, strut amplitude, and radius of curvature), and by the presence or lack of the longitudinal connector. Results: Stagnation regions were localized around stent struts. The regions of low WSS are larger distal to the strut. Under low flow conditions, the percentage restoration of mean axial WSS between struts was lower than that for the high flow by 10-12 %. The largest mean transverse shear stresses were 30 50 % of the largest mean axial shear flow. The percentage restoration in WSS in in the models without the longitudinal connector was as much as 11 % larger than with the connector. The mean axial WSS restoration between the struts was larger for the stent model with larger interstrut spacing. Conclusion: The results indicate that stent design is crucial in determining the fluid mechanical environment in an artery. The sensitivity of flow characteristics to strut configuration could be partially responsible for the dependence of restenosis on stent design. From a fluid dynamics point of view, interstrut spacing should be larger in order to restore the disturbed flow; struts should be oriented to the flow direction in order to reduce the area of flow recirculation. Longitudinal connectors should be used only as necessary, and should be parallel to the axis. These results could guide future stent designs toward reducing restenosis.
引用
收藏
页码:637 / 647
页数:11
相关论文
共 31 条
[1]   CHANGES IN ARTERIAL-WALL COMPLIANCE AFTER ENDOVASCULAR STENTING [J].
BACK, M ;
KOPCHOK, G ;
MUELLER, M ;
CAVAYE, D ;
DONAYRE, C ;
WHITE, RA .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) :905-911
[2]   Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress [J].
Benard, N ;
Coisne, D ;
Donal, E ;
Perrault, R .
JOURNAL OF BIOMECHANICS, 2003, 36 (07) :991-998
[3]   Experimental and computational flow evaluation of coronary stents [J].
Berry, JL ;
Santamarina, A ;
Moore, JE ;
Roychowdhury, S ;
Routh, WD .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (04) :386-398
[4]   Gene expression profiling of human aortic endothelial cells exposed to disturbed flow and steady laminar flow [J].
Brooks, AR ;
Lelkes, PI ;
Rubanyi, GM .
PHYSIOLOGICAL GENOMICS, 2002, 9 (01) :27-41
[5]   Augmentation of wall shear stress inhibits neointimal hyperplasia after stent implantation - Inhibition through reduction of inflammation? [J].
Carlier, SG ;
van Damme, LCA ;
Blommerde, CP ;
Wentzel, JJ ;
van Langehove, G ;
Verheye, S ;
Kockx, MM ;
Knaapen, MWM ;
Cheng, C ;
Gijsen, F ;
Duncker, DJ ;
Stergiopulos, N ;
Slager, CJ ;
Serruys, PW ;
Krams, R .
CIRCULATION, 2003, 107 (21) :2741-2746
[6]  
Fung Y., 1993, BIOMECHANICS MECH PR
[7]   Stent and artery geometry determine intimal thickening independent of arterial injury [J].
Garasic, JM ;
Edelman, ER ;
Squire, JC ;
Seifert, P ;
Williams, MS ;
Rogers, C .
CIRCULATION, 2000, 101 (07) :812-818
[8]  
HENRY FS, 2003, INTRA EXTRACORPOREAL, P333
[9]   Serial intravascular ultrasound predictors of restenosis at the margins of Palmaz-Schatz stents [J].
Hoffmann, R ;
Mintz, GS ;
Kent, KM ;
Satler, LF ;
Pichard, AD ;
Popma, JJ ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (07) :951-&
[10]   Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents [J].
Hoffmann, R ;
Mintz, GS ;
Mehran, R ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Popma, JJ ;
Wu, HS ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) :43-49