Sixteen-row multislice computed tomography: Basic concepts, protocols, and enhanced clinical applications

被引:37
作者
Cademartiri, F
Luccichenti, G
van der Lugt, A
Pavone, P
Pattynama, PM
de Feyter, PJ
Krestin, GP
机构
[1] Erasmus MC, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[2] Univ Parma, Dept Radiol, I-43100 Parma, Italy
[3] Erasmus MC, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
关键词
D O I
10.1053/j.sult.2003.12.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Since its introduction, spiral computed tomography (CT) technology underwent a continuous and fast technical and clinical development. In particular, spatial and temporal resolutions were constantly increased during the last decade. The main breakthrough for clinical application was the introduction of multislice technology, first with 2-row and 4-row equipment and more recently with 16-row scanners. A high-resolution sub-millimeter CT dataset can be acquired easily, although with an increased x-ray exposure for the patient. The high speed of the scan requires up-to-date and careful protocol optimization. Scanner technology and geometry affect image formation procedure and imaging protocols should be adapted accordingly. The technical foundations of spiral CT imaging and the main scan and reconstruction parameters are described in this article. Updated protocols and clinical examples of the latest applications are also discussed. © 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:2 / 16
页数:15
相关论文
共 40 条
[1]
HEPATIC SPIRAL CT - REDUCTION OF DOSE OF INTRAVENOUS CONTRAST MATERIAL [J].
BRINK, JA ;
HEIKEN, JP ;
FORMAN, HP ;
SAGEL, SS ;
MOLINA, PL ;
BROWN, PC .
RADIOLOGY, 1995, 197 (01) :83-88
[2]
THEORY OF IMAGE RECONSTRUCTION IN COMPUTED TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
RADIOLOGY, 1975, 117 (03) :561-572
[3]
Parameters affecting bolus geometry in CTA: A review [J].
Cademartiri, F ;
van der Lugt, A ;
Luccichenti, G ;
Pavone, P ;
Krestin, GP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (04) :598-607
[4]
CADEMARTIRI F, 2003, HEART, V8, P586
[5]
CADEMARTIRI F, 2003, HEART, V8, P970
[6]
Radiation exposure in multi-slice CT of the heart [J].
Cohnen, M ;
Poll, L ;
Püttmann, C ;
Ewen, K ;
Mödder, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04) :295-299
[7]
COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION [J].
CRAWFORD, CR ;
KING, KF .
MEDICAL PHYSICS, 1990, 17 (06) :967-982
[8]
Blurring of vessels in spiral CT angiography: Effects of collimation width, pitch, viewing plane, and windowing in maximum intensity projection [J].
Diederichs, CG ;
Keating, DP ;
Glatting, G ;
Oestmann, JW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (06) :965-974
[9]
Stair-step artifacts with single versus multiple detector-row helical CT [J].
Fleischmann, D ;
Rubin, GD ;
Paik, DS ;
Yen, SY ;
Hilfiker, PR ;
Beaulieu, CF ;
Napel, S .
RADIOLOGY, 2000, 216 (01) :185-196
[10]
Image reconstruction and image quality evaluation for a 16-slice CT scanner [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Polacin, A ;
Schaller, S .
MEDICAL PHYSICS, 2003, 30 (05) :832-845