Analysis of ectasia after laser in situ keratomileusis: Risk factors

被引:176
作者
Binder, Perry S.
机构
[1] a private clinical practice, San Diego, CA
关键词
D O I
10.1016/j.jcrs.2007.04.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To examine a database of laser in situ keratomileusis (LASIK) procedures for preoperative and operative factors assumed to increase the risk for developing post-LASIK ectasia. SETTING: Private clinical practice. METHODS: A computer database was queried for eyes that had LASIK for myopic refractive errors with the following characteristics: preoperative corneal thickness 500 mu m or less, mean keratometry greater than 47.0 diopters (D), patient age 25 years or younger, attempted correction greater than -8.0 D, refractive astigmatism not with-the-rule and greater than 2.0 D, and residual stromal bed thickness (RST) 250 mu m or less. Flap thickness and RST were measured using ultrasound pachymetry. All recorded information was exported to MS Excel and analyzed for eyes that had ectasia. RESULTS: Of the 9700 eyes in the database, none with the above characteristics developed ectasia over mean follow-up periods exceeding 2 years. Seven eyes had multiple risk factors without ectasia. Three eyes with abnormal preoperative topography developed ectasia. CONCLUSIONS: Individual preoperative and operative factors did not in and of themselves increase the risk for ectasia. Unmeasured and unknown factors that affect the individual cornea's biomechanical stability, in combination with some suspected risk factors as well as the current inability to identify corneas at risk for developing ectatic disorders, probably account for most eyes that develop ectasia today.
引用
收藏
页码:1530 / 1538
页数:9
相关论文
共 61 条
[31]  
Kamiya Kazutaka, 2003, Semin Ophthalmol, V18, P17, DOI 10.1080/08820530390897756
[32]   Corneal ectasia after laser in situ keratomileusis in patients without apparent preoperative risk factors [J].
Klein, Shawn R. ;
Epstein, Randy J. ;
Randleman, J. Bradley ;
Stulting, R. Doyle .
CORNEA, 2006, 25 (04) :388-403
[35]  
Lifshitz T, 2005, J REFRACT SURG, V21, P494
[36]   Determining in vivo biomechanical properties of the cornea with an ocular response analyzer [J].
Luce, DA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :156-162
[37]   Inferior corneal steepening after a partial flap without laser ablation mimicking corneal ectasia [J].
Lyle, WA ;
Jin, GJC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (08) :1626-1629
[38]   Hyperopic automated lamellar keratoplasty - Complications and visual results [J].
Lyle, WA ;
Jin, GJC .
ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (04) :425-428
[39]   Repeatability and reproducibility of posterior corneal curvature measurements by combined scanning-slit and placido-disc topography after LASIK [J].
Maldonado, Miguel J. ;
Nieto, Juan C. ;
Diez-Cuenca, Maite ;
Pinero, David P. .
OPHTHALMOLOGY, 2006, 113 (11) :1918-1926
[40]   Corneal ectasia after photorefractive keratectomy for low myopia [J].
Malecaze, F ;
Coullet, J ;
Calvas, P ;
Fournié, P ;
Arné, JL ;
Brodaty, C .
OPHTHALMOLOGY, 2006, 113 (05) :742-746