Defining the limitations of measurements from Doppler spectral recordings

被引:12
作者
Bascom, PAJ
Johnston, KW
Cobbold, RSC
Ojha, M
机构
[1] UNIV TORONTO, INST BIOMED ENGN, TORONTO, ON, CANADA
[2] UNIV TORONTO, DEPT SURG, TORONTO, ON, CANADA
基金
英国医学研究理事会;
关键词
D O I
10.1016/S0741-5214(96)70142-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The purpose of this study was to determine whether Doppler measurements of peak velocity and four other quantitative measures of spectral shape are affected significantly by the site of the Doppler recording in relation to the location of the maximum stenosis. Method: Continuous-wave and pulsed Doppler recordings were made distal to a 70% (area reduction or 45% diameter reduction) asymmetric stenosis in an in vitro flow model under steady and pulsatile flow conditions. Recordings were taken at six different locations proximal and distal to the stenosis. A photochromic dye technique was used to visualize the actual flow field in the model. Results: Distal to the stenosis, the flow visualization results demonstrated a strong radial and axial variation of the velocity held and thus explained why the Doppler measurements of peak frequency and spectral broadening were strongly dependent on the recording site. The peak frequency was maximum within the throat of the stenosis and returned to the prestenotic value five tube diameters distal to the stenosis. Other measurements of spectral broadening and spectral shape varied greatly depending on the location of the recording site in the poststenotic region. Higher order spectral moments such as the coefficient of kurtosis were found to exhibit large temporal variability, which makes them inappropriate as diagnostic indicators. Conclusions: Because of the complex nature of the poststenotic flow field, these results clearly demonstrate that no single Doppler measurement can accurately quantify the severity of a stenosis. Of the Doppler measurements only peak velocity is related to the severity of stenosis. Reproducible peak velocity measurements are obtained only if the Doppler sample volume is positioned at or very near the throat of the stenosis and at an appropriate radial site that may not necessarily be at the center of the vessel.
引用
收藏
页码:34 / 45
页数:12
相关论文
共 22 条
  • [1] INFLUENCE OF SPECTRAL BROADENING ON CONTINUOUS WAVE DOPPLER ULTRASOUND SPECTRA - A GEOMETRIC APPROACH
    BASCOM, PAJ
    COBBOLD, RSC
    ROELOFS, BHM
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (05) : 387 - 395
  • [2] EFFECTS OF TRANSDUCER BEAM GEOMETRY AND FLOW VELOCITY PROFILE ON THE DOPPLER POWER SPECTRUM - A THEORETICAL-STUDY
    BASCOM, PAJ
    COBBOLD, RSC
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (03) : 279 - 295
  • [3] ON THE DOPPLER SIGNAL FROM A STEADY FLOW ASYMMETRICAL STENOSIS MODEL - EFFECTS OF TURBULENCE
    BASCOM, PAJ
    COBBOLD, RSC
    ROUTH, HF
    JOHNSTON, KW
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (03) : 197 - 210
  • [4] BASCOM PAJ, 1990, IEEE EMBS C P PHIL N, P557
  • [5] BASCOM PAJ, 1988, THESIS U TORONTO
  • [6] BASCOM PJ, 1995, THESIS U TORONTO
  • [7] VARIATION OF DOPPLER ULTRASOUND SPECTRAL WIDTH IN THE POST-STENOTIC VELOCITY-FIELD
    CAMPBELL, JD
    HUTCHISON, KJ
    KARPINSKI, E
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (07) : 611 - 619
  • [8] THE EFFECT OF AVERAGING CARDIAC DOPPLER SPECTROGRAMS ON THE REDUCTION OF THEIR AMPLITUDE VARIABILITY
    CLOUTIER, G
    ALLARD, L
    GUO, Z
    DURAND, LG
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (02) : 177 - 186
  • [9] AN INVITRO MODEL AND ITS APPLICATION FOR THE STUDY OF CAROTID DOPPLER SPECTRAL BROADENING
    DOUVILLE, Y
    JOHNSTON, KW
    KASSAM, M
    ZUECH, P
    COBBOLD, RSC
    JARES, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (04) : 347 - 356
  • [10] A PULSE-FOOT-SEEKING ALGORITHM FOR DOPPLER ULTRASOUND WAVEFORMS
    EVANS, DH
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (03): : 267 - 271