Nanoflow gradient generator for capillary high-performance liquid chromatography

被引:28
作者
Deguchi, K [1 ]
Ito, S
Yoshioka, S
Ogata, I
Takeda, A
机构
[1] Hitachi High Technol Co, Hitachinaka 3128504, Japan
[2] Hokkaido Univ, Grad Sch Sci, Div Biol Sci, Sapporo, Hokkaido 0010021, Japan
关键词
D O I
10.1021/ac0350312
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method of generating a nanoflow gradient elution for a capillary high-performance liquid chromatography (HPLC) system has been developed. An important feature of this system is that any gradient (GR) profile generated by a conventional microflow GR pump can be asymptotically traced and converted as a corresponding nanoflow GR profile simply by using a 10-port switching valve with two injection loops installed. Consequently, it has been called an "asymptotic trace 10-port valve" (AT10PV) nanoflow GR generator. Performance of the AT10PV nanoflow GR generator was tested in the range of flow rates from 50 to 500 nL/min. The test demonstrated that the AT10PV nanoflow GR generator can asymptotically trace the original gradient profile with good reproducibility. A capillary HPLC system using the AT10PV nanoflow GR generator provides reasonably good repeatability of peak retention times on the chromatogram of the tryptic digest of a BSA sample, RSD of less than 0.3% at a flow rate of 200 nL/min. It also enables sequential running of a series of sample injections in the same manner as conventional analysis at microflow rates.
引用
收藏
页码:1524 / 1528
页数:5
相关论文
共 36 条
[21]   A direct nanoflow liquid chromatography - Tandem system for interaction proteomics [J].
Natsume, T ;
Yamauchi, Y ;
Nakayama, H ;
Shinkawa, T ;
Yanagida, M ;
Takahashi, N ;
Isobe, T .
ANALYTICAL CHEMISTRY, 2002, 74 (18) :4725-4733
[22]   RECENT ADVANCES IN MICROCOLUMN LIQUID-CHROMATOGRAPHY [J].
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1988, 60 (08) :A500-&
[23]  
NOVOTNY M, 1981, ANAL CHEM, V53, P1294
[24]   MODE OF OPERATION AND PERFORMANCE-CHARACTERISTICS OF MICROBORE COLUMNS FOR USE IN LIQUID-CHROMATOGRAPHY [J].
SCOTT, RPW ;
KUCERA, P .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :51-72
[25]   EXCLUSION PROPERTIES OF SOME COMMERCIALLY AVAILABLE SILICA-GELS [J].
SCOTT, RPW ;
KUCERA, P .
JOURNAL OF CHROMATOGRAPHY, 1976, 125 (01) :251-263
[26]   High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics [J].
Shen, YF ;
Zhao, R ;
Berger, SJ ;
Anderson, GA ;
Rodriguez, N ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4235-4249
[27]   Gas-pressure-driven stepwise-gradient elution system for microcolumn liquid chromatography [J].
Takeuchi, T ;
Lim, LW .
BUNSEKI KAGAKU, 2001, 50 (12) :825-828
[28]   STEPWISE GRADIENT ELUTION USING SWITCHING VALVES IN MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
TAKEUCHI, T ;
NIWA, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1987, 405 :117-124
[29]   HIGH-BACK-PRESSURE LIQUID-CHROMATOGRAPHY .2. DEVELOPMENT OF A POST-COLUMN-CONTROLLED FLOW SYSTEM [J].
TAKEUCHI, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1982, 239 (APR) :633-641
[30]   CONTINUOUS GRADIENT ELUTION IN MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
TAKEUCHI, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1982, 253 (01) :41-47