Recent progress in high-performance capillary bioseparations

被引:25
作者
Huck, CW [1 ]
Stecher, G [1 ]
Bakry, R [1 ]
Bonn, GK [1 ]
机构
[1] Leopold Franzens Univ, Inst Anal Chem & Radiochem, A-6020 Innsbruck, Austria
关键词
bioanalysis; capillary electrochromatography; capillary electrophoresis; capillary liquid chromatography; review;
D O I
10.1002/elps.200305717
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bioanalysis is a fast growing domain with new technological developments in the field of mass spectrometry, separation science, and bioinformatics. The central role of separation prior to detection and evaluation of analytes is indisputable. In fact, since the decipherment of the human genome via multichannel capillary electrophoresis in combination with laser-induced fluorescence [1], the analysis of the proteome, i.e., the type and amount of all proteins expressed at a certain time by the genome in a cell or tissue [2] became of central interest. Therefore, new fast and sensitive capillary liquid chromatographic, electrophoretic, and electrochromatographic separation techniques, suitable for high-throughput analysis of proteins, peptides and nucleic acids, are required.
引用
收藏
页码:3977 / 3997
页数:21
相关论文
共 228 条
[31]  
Dulay MT, 2002, J SEP SCI, V25, P3, DOI 10.1002/1615-9314(20020101)25:1/2<3::AID-JSSC3>3.0.CO
[32]  
2-L
[33]  
Elgstoen KBP, 1999, CHROMATOGRAPHIA, V49, pS79
[34]   Reversed-phase electrochromatography of proteins on modified continuous beds using normal-flow and counterflow gradients.: Theoretical and practical considerations [J].
Ericson, C ;
Hjertén, S .
ANALYTICAL CHEMISTRY, 1999, 71 (08) :1621-1627
[35]   Data-dependent modulation of solid phase extraction capillary electrophoresis for the analysis of complex peptide and phosphopeptide mixtures by tandem mass spectrometry: Application to endothelial nitric oxide synthase [J].
Figeys, D ;
Corthals, GL ;
Gallis, B ;
Goodlett, DR ;
Ducret, A ;
Corson, MA ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2279-2287
[36]   DNA-binding affinities of MyoD and E47 homo- and hetero-dimers by capillary electrophoresis mobility shift assay [J].
Foulds, GJ ;
Etzkorn, FA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 862 (02) :231-236
[37]  
Galloway M, 2002, ELECTROPHORESIS, V23, P3760, DOI 10.1002/1522-2683(200211)23:21<3760::AID-ELPS3760>3.0.CO
[38]  
2-V
[39]   Automated identification of amino acid sequence variations in proteins by HPLC/microspray tandem mass spectrometry [J].
Gatlin, CL ;
Eng, JK ;
Cross, ST ;
Detter, JC ;
Yates, JR .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :757-763
[40]   Effect of analyte adsorption on the electroosmotic flow in microfluidic channels [J].
Ghosal, S .
ANALYTICAL CHEMISTRY, 2002, 74 (04) :771-775