Non-invasive estimation of cardiac output in critical care patients

被引:18
作者
Gerhardt, UMW [1 ]
Schöller, C [1 ]
Böcker, D [1 ]
Hohage, H [1 ]
机构
[1] Univ Munster, Med Poliklin, Dept Internal Med, D-48149 Munster, Germany
关键词
Portapres device; thermodilution method; cardiac output; critical care unit; hemodynamics; Bland and Altman Statistics; sepsis; respiratory problems; catecholamines; finger arterial perfusion;
D O I
10.1023/A:1011481115195
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. This study was carried out to compare cardiac output measurements determined by thermodilution and by Portapres, a non-invasive system. Design, patients and setting. Eighty-seven non-invasive blood pressure measurements were performed in 46 patients in our critical care unit utilising the new, non-invasive Portapres system. Cardiac output values were obtained from these blood pressure values using an aortic impendance model and compared to cardiac output values estimated by the thermodilution technique. Measurements and main results. Statistically significant (p < 0.01) differences (2.3 l/min; limits of agreement +/- 5 l/min) were noted between invasive and non-invasive cardiac output measurements. Differences in measured cardiac outputs increased for patients receiving catecholamine therapy, in patients with hemodynamic instability (e.g., sepsis and cardiac insufficiency), in patients with artificial ventilation, in patients with long duration of intensive care, in younger (< 60 yr) patients and in women. We found no influence of the body mass index (BMI) on the accuracy of Portapres results. In only one single subgroup, 10 patients with pulmonary diseases, Portapres measurements were not statistically significant different from reference results. Conclusions. To date, Portapres measurements cannot replace thermodilution cardiac output estimations. Fluctuations of finger arterial perfusion due to hemodynamic instability, hypothermia and catecholamines may be responsible for problems of Portapres use in critically ill patients.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 25 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   THE RELIABILITY OF NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT IN PATIENTS WITH BOTH HYPERTENSION AND VASCULAR-DISEASE [J].
BOS, WJW ;
IMHOLZ, BPM ;
VANGOUDOEVER, J ;
WESSELING, KH ;
VANMONTFRANS, GA .
AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (08) :529-535
[3]   EFFECT OF REGIONAL AND SYSTEMIC CHANGES IN VASOMOTOR TONE ON FINGER PRESSURE AMPLIFICATION [J].
BOS, WJW ;
VANDENMEIRACKER, AH ;
WESSELING, KH ;
SCHALEKAMP, MADH .
HYPERTENSION, 1995, 26 (02) :315-320
[4]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[5]   Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients - Comparison with thermodilution [J].
Estagnasie, P ;
Djedaini, K ;
Mier, L ;
Coste, F ;
Dreyfuss, D .
INTENSIVE CARE MEDICINE, 1997, 23 (07) :753-759
[6]   Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform [J].
Hirschl, MM ;
Binder, M ;
Gwechenberger, M ;
Herkner, H ;
Bur, A ;
Kittler, H ;
Laggner, AN .
CRITICAL CARE MEDICINE, 1997, 25 (11) :1909-1914
[8]   Non-invasive cardiac output assessment during moderate exercise:: pulse contour compared with CO2 rebreathing [J].
Houtman, S ;
Oeseburg, B ;
Hopman, MTE .
CLINICAL PHYSIOLOGY, 1999, 19 (03) :230-237
[9]   Measurement of cardiac output by pulse dye densitometry using indocyanine green - A comparison with the thermodilution method [J].
Imai, T ;
Takahashi, K ;
Fukura, H ;
Morishita, Y .
ANESTHESIOLOGY, 1997, 87 (04) :816-822
[10]  
IMHOLZ BPM, 1992, J HYPERTENS, V10, P979