Fluorescence-based assay with enzyme amplification on a micro-flow immunosensor chip for monitoring coplanar polychlorinated biphenyls

被引:49
作者
Endo, T
Okuyama, A
Matsubara, Y
Nishi, K
Kobayashi, M
Yamamura, S
Morita, Y
Takamura, Y
Mizukami, H
Tamiya, E
机构
[1] JAIST, Sch Mat Sci, Tatsunokuchi, Ishikawa 9231292, Japan
[2] EnBioTec Labs Co Ltd, Koto Ku, Tokyo 1358073, Japan
关键词
microfluidics; biosensor; ELISA; coplanar polychlorinated biphenyls (Co-PCB); environmental monitoring;
D O I
10.1016/j.aca.2004.08.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detection cf pollutants is of significant importance for environmental protection. However, conventional monitoring methods are often time-consuming, and require expensive equipments. Biosensors based on enzyme linked immunosorbent assay (ELISA) provide an alternative method to conventional ones. In this research, the reduction in the size of ELISA utilizing micro-chemical reaction is described in a micro-flow immunosensor chip. The immunosensor chips were fabricated by micro-electromechanical system (MEMS) technology. The quantitative determination of coplanar polychlorinated biphenyls (Co-PCBs) was performed by using a micro-flow immunosensor chip. Polystyrene beads were used as the solid substrate for the immobilization of Co-PCB antibody. The antibody-immobilized beads were introduced into the flow channel. As a competitive ELISA, sample solution mixed with horseradish peroxidase (HRP) conjugated antigen, and non-HRP conjugated antigen was allowed to react in the flow channel. After the antigen-antibody reaction, addition of phosphate buffer solution containing hydrogen peroxide and the fluorogenic substrate produced a fluorescent dye, which was monitored with the resulting change in the fluorescence intensity. By using our micro-flow immunosensor chip, it was possible to determine the sensing range of Co-PCB derivatives up to 0.1 ppt in 30 s. This immunosensor chip had a wide linear range for Co-PCB detection from 0.1 pg/ml to 1.0 mu g/ml. The regression analysis provided the correlation coefficients of r = 0.982-0.964 with good reproducibility and precision. In a series of five measurements with immunosensor chips prepared with a new batch of antibody-immobilized polystyrene beads, a relative standard deviation of 21.3% was obtained. Our immunosensor chip design reported here has the potential to be implemented to several different detection methodologies for numerous analytes. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 36 条
  • [1] Combinatorial bio/chemical analysis of dioxin and dioxin-like compounds in waste recycling, feed/food, humans/wildlife and the environment
    Behnisch, PA
    Hosoe, K
    Sakai, S
    [J]. ENVIRONMENT INTERNATIONAL, 2001, 27 (06) : 495 - 519
  • [2] Bioanalytical screening methods for dioxins and dioxin-like compounds - a review of bioassay/biomarker technology
    Behnisch, PA
    Hosoe, K
    Sakai, S
    [J]. ENVIRONMENT INTERNATIONAL, 2001, 27 (05) : 413 - 439
  • [3] BIOMARKERS AND BIOASSAYS AS ALTERNATIVE SCREENING METHODS FOR THE PRESENCE AND EFFECTS OF PCDD, PCDF AND PCB
    BOSVELD, ATCB
    VANDENBERG, M
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (1-2): : 106 - 110
  • [4] BROUWER A, 1995, EUR J PHARM-ENVIRON, V293, P1
  • [5] CHARACTERIZATION OF BROMINATED AND BROMO CHLORO DIBENZO-(P)UNDER-BAR-DIOXINS AND DIBENZOFURANS BY GAS-CHROMATOGRAPHY MATRIX ISOLATION-INFRARED SPECTROMETRY
    CHILDERS, JW
    WILSON, NK
    HARLESS, RL
    BARBOUR, RK
    [J]. CHEMOSPHERE, 1992, 25 (7-10) : 1285 - 1290
  • [6] ULTRATRACE DIOXIN AND DIBENZOFURAN ANALYSIS - 30 YEARS OF ADVANCES
    CLEMENT, RE
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (23) : A1130 - +
  • [7] Clement RE, 1999, ANAL CHEM, V71, p257R, DOI 10.1021/a1990012w
  • [8] DENISON MS, 1991, CHEMOSPHERE, V25, P1825
  • [9] Development and characterization of an ELISA assay in PDMS microfluidic channels
    Eteshola, E
    Leckband, D
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (02) : 129 - 133
  • [10] MULTIPLEXED BIOCHEMICAL ASSAYS WITH BIOLOGICAL CHIPS
    FODOR, SPA
    RAVA, RP
    HUANG, XHC
    PEASE, AC
    HOLMES, CP
    ADAMS, CL