Fluorescence-based assay with enzyme amplification on a micro-flow immunosensor chip for monitoring coplanar polychlorinated biphenyls

被引:49
作者
Endo, T
Okuyama, A
Matsubara, Y
Nishi, K
Kobayashi, M
Yamamura, S
Morita, Y
Takamura, Y
Mizukami, H
Tamiya, E
机构
[1] JAIST, Sch Mat Sci, Tatsunokuchi, Ishikawa 9231292, Japan
[2] EnBioTec Labs Co Ltd, Koto Ku, Tokyo 1358073, Japan
关键词
microfluidics; biosensor; ELISA; coplanar polychlorinated biphenyls (Co-PCB); environmental monitoring;
D O I
10.1016/j.aca.2004.08.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detection cf pollutants is of significant importance for environmental protection. However, conventional monitoring methods are often time-consuming, and require expensive equipments. Biosensors based on enzyme linked immunosorbent assay (ELISA) provide an alternative method to conventional ones. In this research, the reduction in the size of ELISA utilizing micro-chemical reaction is described in a micro-flow immunosensor chip. The immunosensor chips were fabricated by micro-electromechanical system (MEMS) technology. The quantitative determination of coplanar polychlorinated biphenyls (Co-PCBs) was performed by using a micro-flow immunosensor chip. Polystyrene beads were used as the solid substrate for the immobilization of Co-PCB antibody. The antibody-immobilized beads were introduced into the flow channel. As a competitive ELISA, sample solution mixed with horseradish peroxidase (HRP) conjugated antigen, and non-HRP conjugated antigen was allowed to react in the flow channel. After the antigen-antibody reaction, addition of phosphate buffer solution containing hydrogen peroxide and the fluorogenic substrate produced a fluorescent dye, which was monitored with the resulting change in the fluorescence intensity. By using our micro-flow immunosensor chip, it was possible to determine the sensing range of Co-PCB derivatives up to 0.1 ppt in 30 s. This immunosensor chip had a wide linear range for Co-PCB detection from 0.1 pg/ml to 1.0 mu g/ml. The regression analysis provided the correlation coefficients of r = 0.982-0.964 with good reproducibility and precision. In a series of five measurements with immunosensor chips prepared with a new batch of antibody-immobilized polystyrene beads, a relative standard deviation of 21.3% was obtained. Our immunosensor chip design reported here has the potential to be implemented to several different detection methodologies for numerous analytes. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 36 条
  • [11] LIGHT-DIRECTED, SPATIALLY ADDRESSABLE PARALLEL CHEMICAL SYNTHESIS
    FODOR, SPA
    READ, JL
    PIRRUNG, MC
    STRYER, L
    LU, AT
    SOLAS, D
    [J]. SCIENCE, 1991, 251 (4995) : 767 - 773
  • [12] SWEDISH DIOXIN SURVEY - EVALUATION OF THE H-4-II E BIOASSAY FOR SCREENING ENVIRONMENTAL-SAMPLES FOR DIOXIN-LIKE ENZYME-INDUCTION
    HANBERG, A
    STAHLBERG, M
    GEORGELLIS, A
    DEWIT, C
    AHLBORG, UG
    [J]. PHARMACOLOGY & TOXICOLOGY, 1991, 69 (06): : 442 - 449
  • [13] SWEDISH DIOXIN SURVEY - DETERMINATION OF 2,3,7,8-TCDD TOXIC EQUIVALENT FACTORS FOR SOME POLYCHLORINATED-BIPHENYLS AND NAPHTHALENES USING BIOLOGICAL TESTS
    HANBERG, A
    WAERN, F
    ASPLUND, L
    HAGLUND, E
    SAFE, S
    [J]. CHEMOSPHERE, 1990, 20 (7-9) : 1161 - 1164
  • [14] An immunoassay for TEQ screening of dioxin/furan samples: Current status of assay and applications development
    Harrison, RO
    Carlson, RE
    [J]. CHEMOSPHERE, 1997, 34 (5-7) : 915 - 928
  • [15] RESULTS OF A 2-YEAR CHRONIC TOXICITY AND ONCOGENICITY STUDY OF 2,3,7,8-TETRACHLORODIBENZO-PARA-DIOXIN IN RATS
    KOCIBA, RJ
    KEYES, DG
    BEYER, JE
    CARREON, RM
    WADE, CE
    DITTENBER, DA
    KALNINS, RP
    FRAUSON, LE
    PARK, CN
    BARNARD, SD
    HUMMEL, RA
    HUMISTON, CG
    [J]. TOXICOLOGY AND APPLIED PHARMACOLOGY, 1978, 46 (02) : 279 - 303
  • [16] Langley Matthew N., 1992, Food and Agricultural Immunology, V4, P143, DOI 10.1080/09540109209354763
  • [17] PECULIARITIES OF THE TOXICITY OF POLYHALOGENATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN ANIMALS AND MAN
    NEUBERT, D
    [J]. CHEMOSPHERE, 1991, 23 (11-12) : 1869 - 1893
  • [18] NEUBERT D, 1991, ORGANOHALOGEN COMPOU, V6, P79
  • [19] Trapping of bead-based reagents within microfluidic systems: On-chip solid-phase extraction and electrochromatography
    Oleschuk, RD
    Shultz-Lockyear, LL
    Ning, YB
    Harrison, DJ
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (03) : 585 - 590
  • [20] OLESCHUK RD, 2000, P MUTAS LYON FRANC, V1, P11