On the effects of gating in diffusion imaging of the brain using single shot EPI

被引:118
作者
Skare, S [1 ]
Andersson, JLR [1 ]
机构
[1] MR Ctr, Dept Clin Neurosci, SE-17176 Stockholm, Sweden
关键词
diffusion tensor imaging; magnetic resonance imaging; cardiac gating; triggering; artifacts;
D O I
10.1016/S0730-725X(01)00415-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To reduce image artifacts in diffusion tensor imaging using single shot EPI, cardiac gating may be performed to prevent brain motion induced signal void in the DWI data. In this work the necessity of performing cardiac gating with single shot echo planar imaging has been explored using F statistics of the variance in DWI data. Peripheral measurement of the cardiac cycle has been employed because of its greater convenience, and hence use, compared to ECG gating. Four volunteers have been studied. Six different trigger delays have been evaluated in the range 18-500 ms relative the peripheral pulse wave. Brain motion was found significant in and inferior to the corpus callosum area. A trigger delay of 500 ms was found to be optimal. However, a long delay allows only for one slice per R-R interval. Therefore, a minimum trigger delay may be the best choice in terms of SNR per unit of experiment time. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:1125 / 1128
页数:4
相关论文
共 17 条
[1]  
Ashburner J, 2000, MED RAD DIA IMG, P285
[2]  
Ashburner J, 1999, HUM BRAIN MAPP, V7, P254, DOI 10.1002/(SICI)1097-0193(1999)7:4<254::AID-HBM4>3.0.CO
[3]  
2-G
[4]   Triggering in quantitative diffusion imaging with single-shot EPI [J].
Brockstedt, S ;
Borg, M ;
Geijer, B ;
Wirestam, R ;
Thomsen, C ;
Holtås, S ;
Ståhlberg, F .
ACTA RADIOLOGICA, 1999, 40 (03) :263-269
[5]   High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging [J].
Brockstedt, S ;
Moore, JR ;
Thomsen, C ;
Holtås, S ;
Ståhlberg, F .
MAGNETIC RESONANCE IMAGING, 2000, 18 (06) :649-657
[6]   EFFECT OF BULK TISSUE MOTION ON QUANTITATIVE PERFUSION AND DIFFUSION MAGNETIC-RESONANCE-IMAGING [J].
CHENEVERT, TL ;
PIPE, JG .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :261-265
[7]   QUANTITATIVE MEASUREMENT OF TISSUE PERFUSION AND DIFFUSION INVIVO [J].
CHENEVERT, TL ;
PIPE, JG ;
WILLIAMS, DM ;
BRUNBERG, JA .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (01) :197-212
[8]   MR DIFFUSION IMAGING OF THE HUMAN BRAIN [J].
CHIEN, D ;
BUXTON, RB ;
KWONG, KK ;
BRADY, TJ ;
ROSEN, BR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) :514-520
[9]   Reducing motion artefacts in diffusion-weighted MRI of the brain: efficacy of navigator echo correction and pulse triggering [J].
Dietrich, O ;
Heiland, S ;
Benner, T ;
Sartor, K .
NEURORADIOLOGY, 2000, 42 (02) :85-91
[10]  
Jones DK, 1999, MAGNET RESON MED, V42, P515, DOI 10.1002/(SICI)1522-2594(199909)42:3<515::AID-MRM14>3.0.CO