Estimation of tissue perfusion by dynamic contrast-enhanced imaging: simulation-based evaluation of the steepest slope method

被引:38
作者
Brix, Gunnar [1 ,2 ]
Zwick, Stefan [3 ,4 ]
Griebel, Juergen [2 ]
Fink, Christian [5 ]
Kiessling, Fabian [6 ]
机构
[1] Bundesamt Strahlenschutz, Abt Med & Beruflichen Strahlenschutz, D-85764 Oberschleissheim, Germany
[2] Fed Off Radiat Protect, Dept Med & Occupat Radiat Protect, Oberschleissheim, Germany
[3] German Canc Res Ctr, Dept Med Phys Radiol, Heidelberg, Germany
[4] Univ Hosp Freiburg, Dept Radiol, Freiburg, Germany
[5] Univ Heidelberg, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, D-6800 Mannheim, Germany
[6] Rhein Westfal TH Aachen, Dept Expt Mol Imaging, Aachen, Germany
关键词
Dynamic-contrast-enhanced imaging; Steepest slope method; Tissue perfusion; Microcirculation; Tracer kinetic modelling; CT; MRI; BLOOD-FLOW; COMPUTED-TOMOGRAPHY; TRACER KINETICS; GD-DTPA; EXCHANGE; VOLUME; CT; CARCINOMA; TRANSPORT; OXYGEN;
D O I
10.1007/s00330-010-1787-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tissue perfusion is frequently determined from dynamic contrast-enhanced CT or MRI image series by means of the steepest slope method. It was thus the aim of this study to systematically evaluate the reliability of this analysis method on the basis of simulated tissue curves. 9600 tissue curves were simulated for four noise levels, three sampling intervals and a wide range of physiological parameters using an axially distributed reference model and subsequently analysed by the steepest slope method. Perfusion is systematically underestimated with errors becoming larger with increasing perfusion and decreasing intravascular volume. For curves sampled after rapid contrast injection with a temporal resolution of 0.72 s, the bias was less than 23% when the mean residence time of tracer molecules in the intravascular distribution space was greater than 6 s. Increasing the sampling interval and the noise level substantially reduces the accuracy and precision of estimates, respectively. The steepest slope method allows absolute quantification of tissue perfusion in a computationally simple and numerically robust manner. The achievable degree of accuracy and precision is considered to be adequate for most clinical applications.
引用
收藏
页码:2166 / 2175
页数:10
相关论文
共 31 条
  • [1] Quantification of renal perfusion using an intravascular contrast agent (Part 1): Results in a canine model
    Aumann, S
    Schoenberg, SO
    Just, A
    Briley-Saebo, K
    Bjornerud, A
    Bock, M
    Brix, G
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 276 - 287
  • [2] TERMINOLOGY FOR MASS-TRANSPORT AND EXCHANGE
    BASSINGTHWAIGHTE, JB
    CHINARD, FP
    CRONE, C
    GORESKY, CA
    LASSEN, NA
    RENEMAN, RS
    ZIERLER, KL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (04): : H539 - H545
  • [3] BLOOD-TISSUE EXCHANGE VIA TRANSPORT AND TRANSFORMATION BY CAPILLARY ENDOTHELIAL-CELLS
    BASSINGTHWAIGHTE, JB
    WANG, CY
    CHAN, IS
    [J]. CIRCULATION RESEARCH, 1989, 65 (04) : 997 - 1020
  • [4] Bassingthwaighte JB., 1984, Handbook of Physiology, P549
  • [5] LIVER PERFUSION STUDIED WITH ULTRAFAST CT
    BLOMLEY, MJK
    COULDEN, R
    DAWSON, P
    KORMANO, M
    DONLAN, P
    BUFKIN, C
    LIPTON, MJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (03) : 424 - 433
  • [6] CONTRAST BOLUS DYNAMIC COMPUTED-TOMOGRAPHY FOR THE MEASUREMENT OF SOLID-ORGAN PERFUSION
    BLOMLEY, MJK
    COULDEN, R
    BUFKIN, C
    LIPTON, MJ
    DAWSON, P
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 : S72 - S77
  • [7] Regional blood flow capillary permeability, and compartmental volumes: Measurement with dynamic CT - Initial experience
    Brix, G
    Bahner, ML
    Hoffmann, UJ
    Horvath, A
    Schreiber, W
    [J]. RADIOLOGY, 1999, 210 (01) : 269 - 276
  • [8] Tracer kinetic modelling of tumour angiogenesis based on dynamic contrast-enhanced CT and MRI measurements
    Brix, Gunnar
    Griebel, Juergen
    Kiessling, Fabian
    Wenz, Frederik
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S30 - S51
  • [9] Pharmacokinetic analysis of tissue microcirculation using nested models: Multimodel inference and parameter identifiability
    Brix, Gunnar
    Zwick, Stefan
    Kiessling, Fabian
    Griebel, Juergen
    [J]. MEDICAL PHYSICS, 2009, 36 (07) : 2923 - 2933
  • [10] REGIONAL LUNG DENSITY AND BLOOD-VOLUME IN NONSMOKING AND SMOKING SUBJECTS MEASURED BY PET
    BRUDIN, LH
    RHODES, CG
    VALIND, SO
    WOLLMER, P
    HUGHES, JMB
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (04) : 1324 - 1334