Estimation of tissue perfusion by dynamic contrast-enhanced imaging: simulation-based evaluation of the steepest slope method

被引:38
作者
Brix, Gunnar [1 ,2 ]
Zwick, Stefan [3 ,4 ]
Griebel, Juergen [2 ]
Fink, Christian [5 ]
Kiessling, Fabian [6 ]
机构
[1] Bundesamt Strahlenschutz, Abt Med & Beruflichen Strahlenschutz, D-85764 Oberschleissheim, Germany
[2] Fed Off Radiat Protect, Dept Med & Occupat Radiat Protect, Oberschleissheim, Germany
[3] German Canc Res Ctr, Dept Med Phys Radiol, Heidelberg, Germany
[4] Univ Hosp Freiburg, Dept Radiol, Freiburg, Germany
[5] Univ Heidelberg, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, D-6800 Mannheim, Germany
[6] Rhein Westfal TH Aachen, Dept Expt Mol Imaging, Aachen, Germany
关键词
Dynamic-contrast-enhanced imaging; Steepest slope method; Tissue perfusion; Microcirculation; Tracer kinetic modelling; CT; MRI; BLOOD-FLOW; COMPUTED-TOMOGRAPHY; TRACER KINETICS; GD-DTPA; EXCHANGE; VOLUME; CT; CARCINOMA; TRANSPORT; OXYGEN;
D O I
10.1007/s00330-010-1787-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tissue perfusion is frequently determined from dynamic contrast-enhanced CT or MRI image series by means of the steepest slope method. It was thus the aim of this study to systematically evaluate the reliability of this analysis method on the basis of simulated tissue curves. 9600 tissue curves were simulated for four noise levels, three sampling intervals and a wide range of physiological parameters using an axially distributed reference model and subsequently analysed by the steepest slope method. Perfusion is systematically underestimated with errors becoming larger with increasing perfusion and decreasing intravascular volume. For curves sampled after rapid contrast injection with a temporal resolution of 0.72 s, the bias was less than 23% when the mean residence time of tracer molecules in the intravascular distribution space was greater than 6 s. Increasing the sampling interval and the noise level substantially reduces the accuracy and precision of estimates, respectively. The steepest slope method allows absolute quantification of tissue perfusion in a computationally simple and numerically robust manner. The achievable degree of accuracy and precision is considered to be adequate for most clinical applications.
引用
收藏
页码:2166 / 2175
页数:10
相关论文
共 31 条
  • [11] Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI
    Buckley, DL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) : 601 - 606
  • [12] DeVries AF, 2001, CANCER RES, V61, P2513
  • [13] Tumoural perfusion as measured by dynamic computed tomography in head and neck carcinoma
    Hermans, R
    Lambin, P
    Van der Goten, A
    Van den Bogaert, W
    Verbist, B
    Weltens, C
    Delaere, PR
    [J]. RADIOTHERAPY AND ONCOLOGY, 1999, 53 (02) : 105 - 111
  • [14] Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA
    Imanishi, Y
    Fukui, A
    Niimi, H
    Itoh, D
    Nozaki, K
    Nakaji, S
    Ishizuka, K
    Tabata, H
    Furuya, Y
    Uzura, M
    Takahama, H
    Hashizume, S
    Arima, S
    Nakajima, Y
    [J]. EUROPEAN RADIOLOGY, 2005, 15 (01) : 41 - 46
  • [15] Perfusion CT in patients with advanced bronchial carcinomas:: a novel chance for characterization and treatment monitoring?
    Kiessling, F
    Boese, J
    Corvinus, C
    Ederle, JR
    Zuna, I
    Schoenberg, SO
    Brix, G
    Schmähl, A
    Tuengerthal, S
    Herth, F
    Kauczor, HU
    Essig, M
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (07) : 1226 - 1233
  • [16] Modeling blood flow heterogeneity
    King, RB
    Raymond, GM
    Bassingthwaighte, JB
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1996, 24 (03) : 352 - 372
  • [17] Increasing Sampling Interval in Cerebral Perfusion CT: Limitation for the Maximum Slope Model
    Kloska, Stephan P.
    Fischer, Tobias
    Sauerland, Cristina
    Buerke, Boris
    Dziewas, Rainer
    Fischbach, Roman
    Heindel, Walter
    [J]. ACADEMIC RADIOLOGY, 2010, 17 (01) : 61 - 66
  • [18] CEREBRAL BLOOD-FLOW, BLOOD-VOLUME AND OXYGEN UTILIZATION - NORMAL VALUES AND EFFECT OF AGE
    LEENDERS, KL
    PERANI, D
    LAMMERTSMA, AA
    HEATHER, JD
    BUCKINGHAM, P
    HEALY, MJR
    GIBBS, JM
    WISE, RJS
    HATAZAWA, J
    HEROLD, S
    BEANEY, RP
    BROOKS, DJ
    SPINKS, T
    RHODES, C
    FRACKOWIAK, RSJ
    JONES, T
    [J]. BRAIN, 1990, 113 : 27 - 47
  • [19] ON THE THEORY OF THE INDICATOR-DILUTION METHOD FOR MEASUREMENT OF BLOOD FLOW AND VOLUME
    MEIER, P
    ZIERLER, KL
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1954, 6 (12) : 731 - 744
  • [20] MEASUREMENT OF TISSUE PERFUSION BY DYNAMIC COMPUTED-TOMOGRAPHY
    MILES, KA
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (761) : 409 - 412