CT Perfusion in Acute Ischemic Stroke: A Comparison of 2-Second and 1-Second Temporal Resolution

被引:50
作者
Abels, B. [1 ]
Klotz, E. [2 ]
Tomandl, B. F. [3 ]
Villablanca, J. P. [4 ]
Kloska, S. P. [5 ]
Lell, M. M. [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Radiol, D-91054 Erlangen, Germany
[2] Siemens Healthcare Sect, Erlangen, Germany
[3] Hosp Bremen Mitte, Dept Neuroradiol, Bremen, Germany
[4] Univ Calif Los Angeles, Dept Neuroradiol, Los Angeles, CA USA
[5] Univ Munster, Dept Clin Radiol, Munster, Germany
关键词
QUANTITATIVE ASSESSMENT; COMPUTED-TOMOGRAPHY; BRAIN; VOLUME; PARAMETERS; EXPOSURE;
D O I
10.3174/ajnr.A2576
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
BACKGROUND AND PURPOSE: CT perfusion data sets are commonly acquired using a temporal resolution of 1 image per second. To limit radiation dose and allow for increased spatial coverage, the reduction of temporal resolution is a possible strategy. The aim of this study was to evaluate the effect of reduced temporal resolution in CT perfusion scans with regard to color map quality, quantitative perfusion parameters, ischemic lesion extent, and clinical decision-making when using DC and MS algorithms. MATERIALS AND METHODS: CTP datasets from 50 patients with acute stroke were acquired with a TR of 1 second. Two-second TA datasets were created by removing every second image. Various perfusion parameters ICBF, CBV, MU, UP, TTD) and color maps were calculated by using identical data-processing settings for 2-second and 1-second TR. Color map quality, quantitative region-of-interest-based perfusion measurements, and TAR/NVT lesions (indicated by CBF/CBV mismatch) derived from the 2-second and 1-second processed data were statistically compared. RESULTS: Color map quality was similar for 2-second versus 1-second TA when using DC and was reduced when using MS. Regarding quantitative values, differences between 2-second and 1-second TA datasets were statistically significant by using both algorithms. Using DC, corresponding tissue-at-risk lesions were slightly smaller at 2-second versus 1-second TR (P<.05), whereas corresponding NVT lesions showed excellent agreement. With MS, corresponding tissue-at-risk lesions showed excellent agreement but more artifacts, whereas NVT lesions were larger (P<.001) compared with 1-second TR. Therapeutic decisions would have remained the same in all patients. CONCLUSIONS: CTP studies obtained with 2-second TA are typically still diagnostic, and the same therapy would have been provided. However, with regard to perfusion quantitation and image-quality based confidence, our study indicates that 1-second TA is preferable to 2-second TR.
引用
收藏
页码:1632 / 1639
页数:8
相关论文
共 21 条
[1]
Perfusion CT in Acute lschemic Stroke: A Qualitative and Quantitative Comparison of Deconvolution and Maximum Slope Approach [J].
Abels, B. ;
Klotz, E. ;
Tomandl, B. F. ;
Kloska, S. P. ;
Lell, M. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (09) :1690-1698
[2]
AJNR Podcast, RAD DOS NEUR CT PROT
[3]
Cohnen M, 2006, AM J NEURORADIOL, V27, P1741
[4]
Dose Exposure of Patients Undergoing Comprehensive Stroke Imaging by Multidetector-Row CT: Comparison of 320-Detector Row and 64-Detector Row CT Scanners [J].
Diekmann, S. ;
Siebert, E. ;
Juran, R. ;
Roll, M. ;
Deeg, W. ;
Bauknecht, H. -C. ;
Diekmann, F. ;
Klingebiel, R. ;
Bohner, G. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (06) :1003-1009
[5]
Hirata Masaaki, 2005, Radiat Med, V23, P162
[6]
Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA [J].
Imanishi, Y ;
Fukui, A ;
Niimi, H ;
Itoh, D ;
Nozaki, K ;
Nakaji, S ;
Ishizuka, K ;
Tabata, H ;
Furuya, Y ;
Uzura, M ;
Takahama, H ;
Hashizume, S ;
Arima, S ;
Nakajima, Y .
EUROPEAN RADIOLOGY, 2005, 15 (01) :41-46
[7]
Dynamic perfusion CT Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients [J].
Kaemena, Andreas ;
Streitparth, Florian ;
Grieser, Christian ;
Lehrnkuhl, Lukas ;
Jamil, Basil ;
Wojtal, Katarzyna ;
Ricke, Jens ;
Pech, Maciej .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 64 (01) :111-118
[8]
Acute stroke assessment with CT: Do we need multimodal evaluation? [J].
Kloska, SP ;
Nabavi, DG ;
Gaus, C ;
Nam, EM ;
Klotz, E ;
Ringelstein, EB ;
Heindel, W .
RADIOLOGY, 2004, 233 (01) :79-86
[9]
Increasing Sampling Interval in Cerebral Perfusion CT: Limitation for the Maximum Slope Model [J].
Kloska, Stephan P. ;
Fischer, Tobias ;
Sauerland, Cristina ;
Buerke, Boris ;
Dziewas, Rainer ;
Fischbach, Roman ;
Heindel, Walter .
ACADEMIC RADIOLOGY, 2010, 17 (01) :61-66
[10]
Perfusion measurements of the brain:: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke [J].
Klotz, E ;
König, M .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 30 (03) :170-184