Six-month clinical and angiographic outcome of the new, less shortening Wallstent in native coronary arteries

被引:38
作者
Ozaki, Y [1 ]
Keane, D [1 ]
Ruygrok, P [1 ]
vanderGiessen, WJ [1 ]
deFeyter, P [1 ]
Serruys, PW [1 ]
机构
[1] ERASMUS UNIV ROTTERDAM,THORAXCTR,CATHETERIZAT LAB,3000 DR ROTTERDAM,NETHERLANDS
关键词
arteries; stents; coronary disease; restenosis; angiography; angioplasty;
D O I
10.1161/01.CIR.93.12.2114
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The new, less shortening, self-expanding Wallstent is characterized by longitudinal flexibility, a protective membrane, a low profile, and a customized range of diameters (3.5 to 6.0 mm). The recent modification of the braiding angle of the Wallstent has resulted in a new device with less shortening on expansion and a concomitant reduction in radial force. We hypothesized that the enforced mechanical remodeling produced by the selection of an oversized Wallstent might result in improved accommodation of subsequent reactive intimal hyperplasia and prevention of chronic recoil of the vessel. Methods and Results To prove this hypothesis, we recently implanted 44 new, less shortening Wallstents in 35 native coronary arteries in 35 patients with acute or threatened closure after balloon angioplasty, according to a strategy of oversizing of Wallstent diameter and complete coverage of the lesion length. The initial and B-month follow-up angiograms were analyzed with a computer-based quantitative coronary angiography (QCA) system. Acute gain (minimal luminal diameter [MLD] post minus MLD pre) and late loss (MLD post minus MLD at follow-up) were examined. Stent deployment was successful in 44 of 44 attempts (100%). Nominal stent diameter used was 1.40 mm larger than the maximal vessel diameter. One patient (3%) with a dilated but unstented lesion proximal to the stented segment sustained a subacute occlusion on day 1 associated with myocardial infarction. Event-free survival at 30 days after stent implantation was 97% (34 of 35 patients). Of the 34 patients eligible for 6-month angiographic follow-up, 3 who were asymptomatic declined repeat angiography. MLD (and percent diameter stenosis [% DS]) changed from 0.83+/-0.50 mm (72%) pre through 3.06+/-0.48 mm (15%) post to 2.27+/-0.74 mm (28%) at follow-up. Acute gain was 2.23+/-0.63 mm, and late loss was 0.78+/-0.61 mm. Angiographic restenosis (>50% DS) was observed in 5 of 31 patients (16%) at 6 months, all of whom underwent repeat angioplasty. Thus, the overall event-free survival at 6-month follow-up was 83% (29 of 35 patients). Conclusions The oversized Wallstent implantation with complete coverage of the lesion length conveyed a favorable B-month clinical and angiographic outcome. The large acute gain obtained by the Wallstent afforded greater accommodation of the subsequent late loss. The enforced mechanical remodeling by oversized new Wallstents may result in prevention of acute and chronic recoil of the vessel wall and subsequently a lower restenosis rate at follow-up.
引用
收藏
页码:2114 / 2120
页数:7
相关论文
共 46 条
  • [31] CORONARY STENTING DECREASES RESTENOSIS IN LESIONS WITH EARLY LOSS IN LUMINAL DIAMETER 24 HOURS AFTER SUCCESSFUL PTCA
    RODRIGUEZ, AE
    SANTAERA, O
    LARRIBAU, M
    FERNANDEZ, M
    SARMIENTO, R
    BALINO, NP
    NEWELL, JB
    ROUBIN, GS
    PALACIOS, IF
    [J]. CIRCULATION, 1995, 91 (05) : 1397 - 1402
  • [32] INTRACORONARY STENTING FOR ACUTE AND THREATENED CLOSURE COMPLICATING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    ROUBIN, GS
    CANNON, AD
    AGRAWAL, SK
    MACANDER, PJ
    DEAN, LS
    BAXLEY, WA
    BRELAND, J
    [J]. CIRCULATION, 1992, 85 (03) : 916 - 927
  • [34] LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF A BALLOON-EXPANDABLE STENT IN THE NATIVE CORONARY CIRCULATION
    SAVAGE, MP
    FISCHMAN, DL
    SCHATZ, RA
    TEIRSTEIN, PS
    LEON, MB
    BAIM, D
    ELLIS, SG
    TOPOL, EJ
    HIRSHFELD, JW
    CLEMAN, MW
    BUCHBINDER, M
    BAILEY, S
    HEUSER, R
    WALKER, CM
    CURRY, RC
    GEBHARDT, S
    RAKE, R
    GOLDBERG, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) : 1207 - 1212
  • [35] EMERGENCY CORONARY STENTING FOR DISSECTION DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - ANGIOGRAPHIC FOLLOW-UP AFTER STENTING AND AFTER REPEAT ANGIOPLASTY OF THE STENTED SEGMENT
    SCHOMIG, A
    KASTRATI, A
    DIETZ, R
    RAUCH, B
    NEUMANN, FJ
    KATUS, HH
    BUSCH, U
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) : 1053 - 1060
  • [36] 4-YEAR EXPERIENCE WITH PALMAZ-SCHATZ STENTING IN CORONARY ANGIOPLASTY COMPLICATED BY DISSECTION WITH THREATENED OR PRESENT VESSEL CLOSURE
    SCHOMIG, A
    KASTRATI, A
    MUDRA, H
    BLASINI, R
    SCHUHLEN, H
    KLAUSS, V
    RICHARDT, G
    NEUMANN, FJ
    [J]. CIRCULATION, 1994, 90 (06) : 2716 - 2724
  • [37] ANGIOGRAPHIC FOLLOW-UP AFTER PLACEMENT OF A SELF-EXPANDING CORONARY-ARTERY STENT
    SERRUYS, PW
    STRAUSS, BH
    BEATT, KJ
    BERTRAND, ME
    PUEL, J
    RICKARDS, AF
    MEIER, B
    GOY, JJ
    VOGT, P
    KAPPENBERGER, L
    SIGWART, U
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (01) : 13 - 17
  • [38] A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    SERRUYS, PW
    DEJAEGERE, P
    KIEMENEIJ, F
    MACAYA, C
    RUTSCH, W
    HEYNDRICKX, G
    EMANUELSSON, H
    MARCO, J
    LEGRAND, V
    MATERNE, P
    BELARDI, J
    SIGWART, U
    COLOMBO, A
    GOY, JJ
    VANDENHEUVEL, P
    DELCAN, J
    MOREL, MA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 489 - 495
  • [39] SERRUYS PW, 1994, QUANTITATIVE ANGIOGR
  • [40] Serruys PW, 1982, TRANSLUMINAL CORONAR, P110