Reproducibility of tumor volume measurement at MicroCT colonography in living mice

被引:18
作者
Durkee, Benjamin Y. [2 ]
Mudd, Sarah R. [3 ]
Roen, Calista N. [4 ]
Clipson, Linda [1 ]
Newton, Michael A. [5 ,6 ,7 ]
Weichert, Jamey P. [2 ,4 ,7 ]
Pickhardt, Perry J. [4 ]
Halberg, Richard B. [1 ]
机构
[1] Univ Wisconsin, Dept Oncol, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Pharm, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[5] Univ Wisconsin, Dept Stat, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Biostat & Med Informat, Madison, WI 53706 USA
[7] Univ Wisconsin, Paul P Carbone Comprehens Canc Ctr, Madison, WI 53706 USA
关键词
microCT virtual colonoscopy; Min mouse; colorectal cancer; tumor volume;
D O I
10.1016/j.acra.2007.10.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Rationale and Objectives. We sought to demonstrate the viability of microcomputed tomographic colonography (mu CTC) as a tool for monitoring tumorigenesis in mouse models of human colorectal cancer during prospective longitudinal studies. The precision and accuracy of volumetric measurements were determined to assess whether changes in tumor volume over time were readily detectable. Materials and Methods. All animal studies were conducted under the guidelines set forth by the Institutional Animal Care and Use Committee of the American Association for Assessment and Accreditation of Laboratory Animal Care. mu CTC was performed on C57BL/6J (B6) mice carrying the Min allele of Apc, ultimately yielding 18 scans. Assessments of scan quality and tumor volume were both performed once per week over 8 weeks. Results. Scans with a good quality rating had a mean standard deviation in tumor volume measurement of 8%. By contrast, scans with a poor quality rating had a mean standard deviation in tumor volume measurement of 35%. Variables affecting mu CTC scan quality in living mice included bowel preparation, motion artifact, and tumor morphology. Tumor volume measurements were highly correlated with tumor weight (r(2) = 0.87). Conclusions. The reproducibility of tumor volume measurement at mu CTC in living. mice makes prospective longitudinal evaluation of colonic tumor response feasible. For mu CTC scans of good quality, a 16% change in tumor volume can be detected at the 95% confidence level.
引用
收藏
页码:334 / 341
页数:8
相关论文
共 9 条
[1]
[Anonymous], CANC FACTS FIG 2007
[2]
HEIDELBERGER C, 1963, CANCER RES, V23, P1226
[3]
Measurement of brain structures with artificial neural networks: Two- and three-dimensional applications [J].
Magnotta, VA ;
Heckel, D ;
Andreasen, NC ;
Cizadlo, T ;
Corson, PW ;
Ehrhardt, JC ;
Yuh, WTC .
RADIOLOGY, 1999, 211 (03) :781-790
[4]
Microcomputed tomography colonography for polyp detection in an in vivo mouse tumor model [J].
Pickhardt, PJ ;
Halberg, RB ;
Taylor, AJ ;
Durkee, BY ;
Fine, J ;
Lee, FT ;
Weichert, JP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (09) :3419-3422
[5]
Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults [J].
Pickhardt, PJ ;
Choi, JR ;
Hwang, I ;
Butler, JA ;
Puckett, ML ;
Hildebrandt, HA ;
Wong, RK ;
Nugent, PA ;
Mysliwiec, PA ;
Schindler, WR .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (23) :2191-2200
[6]
Quon A, 2006, J NUCL MED, V47, P1081
[7]
MULTIPLE INTESTINAL NEOPLASIA CAUSED BY A MUTATION IN THE MURINE HOMOLOG OF THE APC GENE [J].
SU, LK ;
KINZLER, KW ;
VOGELSTEIN, B ;
PREISINGER, AC ;
MOSER, AR ;
LUONGO, C ;
GOULD, KA ;
DOVE, WF .
SCIENCE, 1992, 256 (5057) :668-670
[8]
LINEAR-MODELS FOR THE ANALYSIS OF LONGITUDINAL-STUDIES [J].
WARE, JH .
AMERICAN STATISTICIAN, 1985, 39 (02) :95-101
[9]
Polyps: Linear and volumetric measurement at CT colonography [J].
Yeshwant, Srinath C. ;
Summers, Ronald M. ;
Yao, Jianhua ;
Brickman, Daniel S. ;
Choi, J. Richard ;
Pickhardt, Perry J. .
RADIOLOGY, 2006, 241 (03) :802-811