Label-free detection of DNA with interdigitated micro-electrodes in a fluidic cell

被引:65
作者
Berdat, Daniel [1 ]
Rodriguez, Ana C. Martin [2 ]
Herrera, Fernando [1 ]
Gijs, Martin A. M. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Microelect & Microsyst, CH-1015 Lausanne, Switzerland
[2] Bionostra SL, Madrid 28760, Spain
关键词
D O I
10.1039/b712609c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We investigate the analytical performance of an interdigitated electrode sensor for the label-free detection of DNA, by monitoring the complex impedance of 5 mm wide interdigitated Pt microelectrodes on a glass substrate. We detect the hybridization of unlabeled 38-mer target ssDNA with a complementary probe that is bound on the glass in between the electrodes by a disuccinimidyl terephtalate and aminosilane immobilization procedure. The sensor is mounted in a microfluidic flow cell, in which hybridization is monitored and in situ compared with a reference. After hybridization, the cell is perfused with deionised water and the dependence of the measured conductance due to the immobilized target DNA layer, to target DNA concentrations down to 1 nM is demonstrated. Subsequently, we apply our sensor to the detection of pathogen DNA from Salmonella choleraesuis in dairy food.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 37 条
[31]   Impedance DNA biosensor using electropolymerized polypyrrole/multiwalled carbon nanotubes modified electrode [J].
Xu, Ying ;
Ye, Xiaoyan ;
Yang, Lin ;
He, Pingang ;
Fang, Yuzhi .
ELECTROANALYSIS, 2006, 18 (15) :1471-1478
[32]   Impedance-based DNA biosensor employing molecular beacon DNA as probe and thionine as charge neutralizer [J].
Xu, Ying ;
Yang, Lin ;
Ye, Xiaoyan ;
He, Pingang ;
Fang, Yuzhi .
ELECTROANALYSIS, 2006, 18 (09) :873-881
[33]   Sequence-selective DNA detection using multiple laminar streams: A novel microfluidic analysis method [J].
Yamashita, K ;
Yamaguchi, Y ;
Miyazaki, M ;
Nakamura, H ;
Shimizu, H ;
Maeda, H .
LAB ON A CHIP, 2004, 4 (01) :1-3
[34]   Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium [J].
Yang, LJ ;
Li, YB ;
Griffis, CL ;
Johnson, MG .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) :1139-1147
[35]   Interdigitated array microelectrode-based electrochemical impedance immunosensor for detection of Escherichia coli O157:H7 [J].
Yang, LJ ;
Li, YB ;
Erf, GF .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1107-1113
[36]   Theoretical and experimental study towards a nanogap dielectric biosensor [J].
Yi, MQ ;
Jeong, KH ;
Lee, LP .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (07) :1320-1326
[37]   Materials and techniques for electrochemical biosensor design and construction [J].
Zhang, S ;
Wright, G ;
Yang, Y .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (5-6) :273-282