Impact of asymmetric stent expansion on neointimal hyperplasia following sirolimus-eluting stent implantation

被引:12
作者
Kaneda, H
Ako, J
Honda, Y
Terashima, M
Morino, Y
Yock, PG
Popma, JJ
Leon, MB
Moses, JW
Fitzgerald, PJ [1 ]
机构
[1] Stanford Univ, Ctr Res Cardiovasc Intervent, Stanford, CA 94305 USA
[2] Brigham & Womens Hosp, Boston, MA 02115 USA
[3] Columbia Univ, New York, NY USA
关键词
D O I
10.1016/j.amjcard.2005.07.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess whether asymmetric stent expansion affects suppression of neointimal hyperplasia after sirolimus-eluting stent implantation, 64 patients in the SIRolImUS-coated Bx Velocity stent trial who underwent single 18-mm stent implantation and 3-dimensional intravascular ultrasonography at 8-month follow-up were enrolled. To assess the longitudinal stent asymmetric expansion, 2 cross sections with a maximal/minimal stent area were chosen in each patient. To assess for tomographic stent asymmetric expansion, stent eccentricity was determined by dividing the minimum stent diameter by the maximum stent diameter. At the 2 cross sections with a maximal/minimal stent area, a sirolimus-eluting stent reduced neointimal hyperplasia significantly with no interaction between the treatment and stent areas. A sirolimus-eluting stent also significantly reduced neointimal hyperplasia in the concentric and eccentric stent groups. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1404 / 1407
页数:4
相关论文
共 20 条
[1]   NEOINTIMA FORMATION AFTER VASCULAR STENT IMPLANTATION - SPATIAL AND CHRONOLOGICAL DISTRIBUTION OF SMOOTH-MUSCLE CELL-PROLIFERATION AND PHENOTYPIC MODULATION [J].
BAI, HZ ;
MASUDA, J ;
SAWA, Y ;
NAKANO, S ;
SHIRAKURA, R ;
SHIMAZAKI, Y ;
OGATA, J ;
MATSUDA, H .
ARTERIOSCLEROSIS AND THROMBOSIS, 1994, 14 (11) :1846-1853
[2]   Relationship between residual atheroma burden and neointimal growth in patients undergoing stenting - Analysis of the atherectomy before MULTI-LlNK improves lumen gain and clinical outcomes trial intravascular ultrasound substudy [J].
Casserly, IP ;
Aronow, HD ;
Schoenhagen, P ;
Tsutsui, H ;
Popovich, J ;
Goormastic, M ;
Popma, JJ ;
Nissen, SE ;
Tuzcu, EM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (09) :1573-1578
[3]   Mechanisms of neointima formation and remodeling in the porcine coronary artery [J].
Christen, T ;
Verin, V ;
Bochaton-Piallat, ML ;
Popowski, Y ;
Ramaekers, F ;
Debruyne, P ;
Camenzind, E ;
van Eys, G ;
Gabbiani, G .
CIRCULATION, 2001, 103 (06) :882-888
[4]   Serial volumetric (three-dimensional) intravascular ultrasound analysis of restenosis after directional coronary atherectomy [J].
de Vrey, EA ;
Mintz, GS ;
von Birgelen, C ;
Kimura, T ;
Noboyoshi, M ;
Popma, JJ ;
Serruys, PW ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1874-1880
[5]   Inhibition of restenosis with a paclitaxel-eluting, polymer-free coronary stent - The European evaLUation of pacliTaxel Eluting Stent (ELUTES) trial [J].
Gershlick, A ;
De Scheerder, I ;
Chevalier, B ;
Stephens-Lloyd, A ;
Camenzind, E ;
Vrints, C ;
Reifart, N ;
Missault, L ;
Goy, JJ ;
Brinker, JA ;
Raizner, AE ;
Urban, P ;
Heldman, AW .
CIRCULATION, 2004, 109 (04) :487-493
[6]   Physiological transport forces govern drug distribution for stent-based delivery [J].
Hwang, CW ;
Wu, D ;
Edelman, ER .
CIRCULATION, 2001, 104 (05) :600-605
[7]   7-hexanoyltaxol-eluting stent for prevention of neointimal growth - An intravascular ultrasound analysis from the study to COmpare REstenosis rate between QueST and QuaDS-QP2 (SCORE) [J].
Kataoka, T ;
Grube, E ;
Honda, Y ;
Morino, Y ;
Hur, SH ;
Bonneau, HN ;
Colombo, A ;
Di Mario, C ;
Guagliumi, G ;
Hauptmann, KE ;
Pitney, MR ;
Lansky, AJ ;
Stertzer, SH ;
Yock, PG ;
Fitzgerald, PJ .
CIRCULATION, 2002, 106 (14) :1788-1793
[8]   Reinjury of arterial lesions induces intimal smooth muscle cell replication that is not controlled by fibroblast growth factor 2 [J].
Koyama, H ;
Reidy, MA .
CIRCULATION RESEARCH, 1997, 80 (03) :408-417
[9]   LOCALIZED ARTERIAL-WALL DRUG-DELIVERY FROM A POLYMER-COATED REMOVABLE METALLIC STENT - KINETICS, DISTRIBUTION, AND BIOACTIVITY OF FORSKOLIN [J].
LAMBERT, TL ;
DEV, V ;
RECHAVIA, E ;
FORRESTER, JS ;
LITVACK, F ;
EIGLER, NL .
CIRCULATION, 1994, 90 (02) :1003-1011
[10]   Non-polymer-based paclitaxel-coated coronary stents for the treatment of patients with de novo coronary lesions - Angiographic follow-up of the DELIVER clinical trial [J].
Lansky, AJ ;
Costa, RA ;
Mintz, GS ;
Tsuchiya, Y ;
Midei, M ;
Cox, DA ;
O'Shaughnessy, C ;
Applegate, RA ;
Cannon, LA ;
Mooney, M ;
Farah, A ;
Tannenbaum, MA ;
Yakubov, S ;
Kereiakes, DJ ;
Wong, SC ;
Kaplan, B ;
Cristea, E ;
Stone, GW ;
Leon, MB ;
Knopf, WD ;
O'Neill, WW .
CIRCULATION, 2004, 109 (16) :1948-1954