共 32 条
Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles
被引:51
作者:
Haentzsch, Madlen
[1
,2
]
Tolios, Alexander
[3
]
Beutner, Frank
[1
,2
,4
]
Nagel, Dorothea
[3
]
Thiery, Joachim
[1
,2
]
Teupser, Daniel
[1
,3
]
Holdt, Lesca M.
[1
,3
]
机构:
[1] Univ Leipzig, LIFE Leipzig Res Ctr Civilizat Dis, D-04109 Leipzig, Germany
[2] Univ Hosp Leipzig, Inst Lab Med Clin Chem & Mol Diagnost, Leipzig, Germany
[3] Univ Munich, Inst Lab Med, Munich, Germany
[4] Univ Leipzig, Ctr Heart, Dept Cardiol, D-04109 Leipzig, Germany
来源:
PLOS ONE
|
2014年
/
9卷
/
12期
关键词:
ACUTE MYOCARDIAL-INFARCTION;
CORONARY-ARTERY-DISEASE;
GENE-EXPRESSION;
MATRIX-METALLOPROTEINASE-9;
COLLECTION;
STABILIZATION;
TRANSCRIPTOME;
SAMPLES;
INJURY;
SEQ;
D O I:
10.1371/journal.pone.0113298
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
Background: Whole blood expression profiling is frequently performed using PAXgene (Qiagen) or Tempus (Life Technologies) tubes. Here, we compare 6 novel generation RNA isolation protocols with respect to RNA quantity, quality and recovery of mRNA and miRNA. Methods: 3 PAXgene and 3 Tempus Tubes were collected from participants of the LIFE study with (n=12) and without (n=35) acute myocardial infarction (AMI). RNA was extracted with 4 manual protocols from Qiagen (PAXgene Blood miRNA Kit), Life Technologies (MagMAX for Stabilized Blood Tubes RNA Isolation Kit), and Norgen Biotek (Norgen Preserved Blood RNA Purification Kit I and Kit II), and 2 (semi-) automated protocols on the QIAsymphony (Qiagen) and MagMAX Express-96 Magnetic Particle Processor (Life Technologies). RNA quantity and quality was determined. For biological validation, RNA from 12 representative probands, extracted with all 6 kits (n=72), was reverse transcribed and mRNAs (matrix metalloproteinase 9, arginase 1) and miRNAs (miR133a, miR1), shown to be altered by AMI, were analyzed. Results: RNA yields were highest using the Norgen Kit I with Tempus Tubes and lowest using the Norgen Kit II with PAXgene. The disease status was the second major determinant of RNA yields (LIFE-AMI 11.2 vs. LIFE 6.7 mu g, p < 0.001) followed by the choice of blood collection tube. (Semi-) automation reduced overall RNA extraction time but did not generally reduce hands-on-time. RNA yields and quality were comparable between manual and automated extraction protocols. mRNA expression was not affected by collection tubes and RNA extraction kits but by RT/qPCR reagents with exception of the Norgen Kit II, which led to mRNA depletion. For miRNAs, expression differences related to collection tubes (miR30b), RNA isolation (Norgen Kit II), and RT/qRT reagents (miR133a) were observed. Conclusion: We demonstrate that novel generation RNA isolation kits significantly differed with respect to RNA recovery and affected miRNA but not mRNA expression profiles.