A generalized approach to parallel magnetic resonance imaging

被引:182
作者
Sodickson, DK
McKenzie, CA
机构
[1] Beth Israel Deaconess Med Ctr, Div Cardiovasc, Dept Med, Boston, MA 02215 USA
[2] Harvard Med Sch, Boston, MA USA
关键词
rapid imaging; parallel MRI; SMASH; SENSE;
D O I
10.1118/1.1386778
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Parallel magnetic resonance (MR) imaging uses spatial encoding from multiple radiofrequency detector coils to supplement the encoding supplied by magnetic field gradients, and thereby to accelerate MR image acquisitions beyond previous limits. A generalized formulation for parallel MR imaging is derived, demonstrating the relationship between existing techniques such as SMASH and SENSE, and suggesting new algorithms with improved performance. Hybrid approaches combining features of both SMASH-like and SENSE-like image reconstructions are constructed, and numerical conditioning techniques are described which can improve the practical robustness of parallel image reconstructions. Incorporation of numerical conditioning directly into parallel reconstructions using the generalized approach also removes a cumbersome and potentially error-prone sensitivity calibration step involving division of two distinct in vivo reference images. Hybrid approaches in combination with numerical conditioning are shown to extend the range of accelerations over which high-quality parallel images may be obtained. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1629 / 1643
页数:15
相关论文
共 47 条
[31]   FAST IMAGING USING SUBENCODING DATA SETS FROM MULTIPLE DETECTORS [J].
RA, JB ;
RIM, CY .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) :142-145
[32]   THE NMR PHASED-ARRAY [J].
ROEMER, PB ;
EDELSTEIN, WA ;
HAYES, CE ;
SOUZA, SP ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :192-225
[33]  
Sodickson D.K., 2000, METHODS BIOMEDICAL M, P239, DOI 10.1002/9780470034590.emrstm0517
[34]  
Sodickson DK, 1999, MAGN RESON MED, V41, P1009, DOI 10.1002/(SICI)1522-2594(199905)41:5<1009::AID-MRM21>3.0.CO
[35]  
2-4
[36]   Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays [J].
Sodickson, DK ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :591-603
[37]   Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: A pilot study [J].
Sodickson, DK ;
McKenzie, CA ;
Li, W ;
Wolff, S ;
Manning, WJ ;
Edelman, RR .
RADIOLOGY, 2000, 217 (01) :284-289
[38]  
Sodickson DK, 2000, MAGN RESON MED, V44, P243, DOI 10.1002/1522-2594(200008)44:2<243::AID-MRM11>3.0.CO
[39]  
2-L
[40]  
SODICKSON DK, 2000, P 8 ANN M ISMRM DENV, P272