Anatomic and Procedural Predictors of Paravalvular Aortic Regurgitation After Implantation of the Medtronic CoreValve Bioprosthesis

被引:216
作者
Sherif, Mohammad A. [1 ]
Abdel-Wahab, Mohamed [1 ]
Stoecker, Bjoern [1 ]
Geist, Volker [1 ]
Richardt, Doreen [2 ]
Toelg, Ralph [1 ]
Richardt, Gert [1 ]
机构
[1] Univ Kiel, Acad Teaching Hosp, Heart & Vasc Ctr, Segeberger Kliniken GmbH, Bad Segeberg, Germany
[2] Schleswig Holstein Univ Hosp, Cardiovasc Surg Dept, Lubeck, Germany
关键词
VALVULAR HEART-DISEASE; VALVE IMPLANTATION; TASK-FORCE; ASSOCIATION; PROSTHESIS; GUIDELINES; MANAGEMENT; STENOSIS; SOCIETY; DEVICE;
D O I
10.1016/j.jacc.2010.06.035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to determine the predictors of aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI). Background TAVI has been associated with a high rate of paravalvular regurgitation, usually mild. Nevertheless, moderate to severe regurgitations still occur and may have negative clinical consequences. Methods Fifty patients with severe aortic stenosis were recruited and underwent successful TAVI with the Medtronic CoreValve bioprosthesis through the transfemoral route. The end point of this study is the early occurrence of significant AR, defined as the occurrence of grade II or more AR by post-procedural aortography. Results The study population's mean age was 80.5 +/- 7.9 years, with a mean aortic valve area of 0.64 +/- 0.17 cm(2). Post-procedural AR was absent in 3 patients and was grade I in 27 patients, grade II in 13 patients, and grade III in 7 patients. Using univariate analysis, the chance of significant AR increased with increasing angle of left ventricular outflow tract to ascending aorta (angle LVOT-AO) (odds ratio: 1.24, p < 0.001). For the depth of the device in relation to the noncoronary cusp, there was a minimum chance of AR corresponding to depth = 9.5 mm (odds ratio: 1.1, p = 0.01). Using multivariate analysis, we found a greater chance of significant AR with a greater angle (odds ratio: 1.24, p = 0.001), and that the chance of significant AR is a minimum when depth of the device in relation to the noncoronary cusp is similar to 10 mm (odds ratio: 1.1, p = 0.024). A predictive model was generated, and if 2 x angle LVOT-AO + (depth to noncoronary cusp - 10)(2) >= 50, the likelihood of occurrence of significant AR could be predicted with a sensitivity of 85% and a specificity of 87%. Conclusions The occurrence of significant AR after TAVI can be predicted by anatomic and procedural variables. A model such as that presented can be used to select suitable patients for this procedure and guide operators during implantation of the device. (J Am Coll Cardiol 2010;56:1623-9) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:1623 / 1629
页数:7
相关论文
共 13 条
  • [1] Energy Loss Due to Paravalvular Leak With Transcatheter Aortic Valve Implantation
    Azadani, Ali N.
    Jaussaud, Nicolas
    Matthews, Peter B.
    Ge, Liang
    Guy, T. Sloane
    Chuter, Timothy A. M.
    Tseng, Elaine E.
    [J]. ANNALS OF THORACIC SURGERY, 2009, 88 (06) : 1857 - 1863
  • [2] Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.hrthm.2008.04.014, 10.1016/j.jacc.2008.05.007]
  • [3] Echocardiography for transcatheter aortic valve implantation
    Chin, Derek
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01): : I21 - I29
  • [4] Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence
    Detaint, Delphine
    Lepage, Laurent
    Himbert, Dominique
    Brochet, Eric
    Messika-Zeitoun, David
    Iung, Bernard
    Vahanian, Alec
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) : 821 - 827
  • [5] Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome
    Grube, Eberhard
    Schuler, Gerhard
    Buellesfeld, Lutz
    Gerckens, Ulrich
    Linke, Axel
    Wenaweser, Peter
    Sauren, Barthel
    Mohr, Friedrich-Wilhelm
    Walther, Thomas
    Zickmann, Bernfried
    Iversen, Stein
    Felderhoff, Thomas
    Cartier, Raymond
    Bonan, Raoul
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) : 69 - 76
  • [6] Association of mitral annular calcification and aortic valve morphology: a substudy of the aortic stenosis progression observation measuring effects of rosuvastatin (ASTRONOMER) study
    Jassal, Davinder S.
    Tam, James W.
    Bhagirath, Kapil M.
    Gaboury, Isabelle
    Sochowski, Randall A.
    Dumesnil, Jean G.
    Giannoccaro, Peter J.
    Jue, John
    Pandey, A. Shekhar
    Joyner, Campbell D.
    Teo, Koon K.
    Chan, Kwan L.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (12) : 1542 - 1547
  • [7] Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis
    Jilaihawi, Hasan
    Chin, Derek
    Spyt, Tomasz
    Jeilan, Mohamed
    Vasa-Nicotera, Mariuca
    Bence, Johan
    Logtens, Elaine
    Kovac, Jan
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (07) : 857 - 864
  • [8] DETERMINATION OF THE STENOTIC AORTIC-VALVE AREA IN ADULTS USING DOPPLER ECHOCARDIOGRAPHY
    OTTO, CM
    PEARLMAN, AS
    COMESS, KA
    REAMER, RP
    JANKO, CL
    HUNTSMAN, LL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (03) : 509 - 517
  • [9] EVALUATION OF AORTIC-INSUFFICIENCY BY DOPPLER COLOR FLOW MAPPING
    PERRY, GJ
    HELMCKE, F
    NANDA, NC
    BYARD, C
    SOTO, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (04) : 952 - 959
  • [10] Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System
    Piazza, N.
    Otten, A.
    Schultz, C.
    Onuma, Y.
    Garcia-Garcia, H. M.
    Boersma, E.
    de Jaegere, P.
    Serruys, P. W.
    [J]. HEART, 2010, 96 (01) : 19 - 26