Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material

被引:309
作者
Wang, BQ
Li, B
Deng, Q
Dong, SJ [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Electroanalyt Chem Lab, Changchun 130022, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Appl Chem, Natl Anal & Res Ctr Electrochem & Spect, Changchun 130022, Peoples R China
关键词
D O I
10.1021/ac980160h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of sol-gel organic-inorganic hybrid material was developed and used for the production of biosensors. This material is composed of silica sol and a grafting copolymer of poly(vinyl alcohol) with 4-vinylpyridine. It prevents the cracking of conventional sol-gel-derived glasses and eliminates the swelling of the hydrogel. The optimum composition of the hybrid material was first examined, and then glucose oxidase was immobilized in this matrix to demonstrate its application. The characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. The biosensor exhibited a series of good properties: high sensitivity (600 nA mmol(-1)L(-1)), short response time (11 s) and remarkable long-term stability in storage (at least 5 months). In addition, the characteristics of the second-generation biosensor with the use of tetrathiafulvalene as a mediator mere discussed.
引用
收藏
页码:3170 / 3174
页数:5
相关论文
共 31 条
[1]   BIOCHEMICALLY ACTIVE SOL-GEL GLASSES - THE TRAPPING OF ENZYMES [J].
BRAUN, S ;
RAPPOPORT, S ;
ZUSMAN, R ;
AVNIR, D ;
OTTOLENGHI, M .
MATERIALS LETTERS, 1990, 10 (1-2) :1-5
[2]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[3]   SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS [J].
DAVE, BC ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :A1120-A1127
[4]   COBALT PORPHYRIN NAFION FILM ON CARBON MICROARRAY ELECTRODE TO MONITOR OXYGEN FOR ENZYME ANALYSIS OF GLUCOSE [J].
DONG, S ;
KUWANA, T .
ELECTROANALYSIS, 1991, 3 (06) :485-491
[5]   ORGANIC-PHASE ENZYME ELECTRODE OPERATED IN WATER-FREE SOLVENTS [J].
DONG, SJ ;
GUO, YZ .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :3895-3899
[6]   ENCAPSULATION OF PROTEINS IN TRANSPARENT POROUS SILICATE-GLASSES PREPARED BY THE SOL-GEL METHOD [J].
ELLERBY, LM ;
NISHIDA, CR ;
NISHIDA, F ;
YAMANAKA, SA ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
SCIENCE, 1992, 255 (5048) :1113-1115
[7]   ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS [J].
FOULDS, NC ;
LOWE, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1259-1264
[8]  
GIBSON TD, 1992, ACS S SER, V487, pCH5
[9]   SOL-GEL VANADIUM PENTAOXIDE GLUCOSE BIOSENSOR [J].
GLEZER, V ;
LEV, O .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (06) :2533-2534
[10]   REDOX POLYMER-FILMS CONTAINING ENZYMES .1. A REDOX-CONDUCTING EPOXY CEMENT - SYNTHESIS, CHARACTERIZATION, AND ELECTROCATALYTIC OXIDATION OF HYDROQUINONE [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5970-5975