A new type of sol-gel organic-inorganic hybrid material was developed and used for the production of biosensors. This material is composed of silica sol and a grafting copolymer of poly(vinyl alcohol) with 4-vinylpyridine. It prevents the cracking of conventional sol-gel-derived glasses and eliminates the swelling of the hydrogel. The optimum composition of the hybrid material was first examined, and then glucose oxidase was immobilized in this matrix to demonstrate its application. The characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. The biosensor exhibited a series of good properties: high sensitivity (600 nA mmol(-1)L(-1)), short response time (11 s) and remarkable long-term stability in storage (at least 5 months). In addition, the characteristics of the second-generation biosensor with the use of tetrathiafulvalene as a mediator mere discussed.
引用
收藏
页码:3170 / 3174
页数:5
相关论文
共 31 条
[11]   Sol-gel derived, ferrocenyl-modified silicate-graphite composite electrode: Wiring of glucose oxidase [J].
Gun, J ;
Lev, O .
ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) :95-106
[12]   ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER [J].
KAMIN, RA ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1198-1205
[13]   KINETIC-STUDY OF THE PERFORMANCE OF 3RD-GENERATION BIOSENSORS [J].
KOOPAL, CGJ ;
NOLTE, RJM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1994, 33 (01) :45-53
[14]  
LEV O, 1992, ANALUSIS, V20, P543
[15]   Synthesis of a self-gelatinizable grafting copolymer of poly(vinyl alcohol) for construction of an amperometric peroxidase electrode [J].
Li, B ;
Niu, L ;
Kou, WP ;
Deng, Q ;
Cheng, GJ ;
Dong, SJ .
ANALYTICAL BIOCHEMISTRY, 1998, 256 (01) :130-132
[16]   Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide [J].
Li, J ;
Tan, SN ;
Ge, HL .
ANALYTICA CHIMICA ACTA, 1996, 335 (1-2) :137-145
[17]  
LUMLEYWOODYEAR T, 1995, ANAL CHEM, V67, P1332
[18]  
MURRAY RW, 1989, ACS S SERIES, V403, pCH5
[19]   GLUCOSE BIOSENSOR BASED ON A SOL-GEL-DERIVED PLATFORM [J].
NARANG, U ;
PRASAD, PN ;
BRIGHT, FV ;
RAMANATHAN, K ;
KUMAR, ND ;
MALHOTRA, BD ;
KAMALASANAN, MN ;
CHANDRA, S .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3139-3144
[20]   SOL-GEL DERIVED RENEWABLE-SURFACE BIOSENSORS [J].
PANKRATOV, I ;
LEV, O .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 393 (1-2) :35-41