Axial and torsional stability of supracondylar femur osteotomies: biomechanical comparison of the stability of five different plate and osteotomy configurations

被引:37
作者
Brinkman, J. -M. [1 ]
Hurschler, C. [2 ]
Agneskirchner, J. D. [3 ]
Freiling, D. [3 ]
van Heerwaarden, R. J. [1 ]
机构
[1] Sint Maartensklin, Limb Deform Reconstruct Unit, Dept Orthopaed, NL-3440 JD Woerden, Netherlands
[2] Hannover Med Sch, Dept Orthopaed, Lab Biomech & Biomat, D-30625 Hannover, Germany
[3] Henriettenstiftung, Dept Trauma & Reconstruct Surg, D-30171 Hannover, Germany
关键词
Distal femur; Osteotomy technique; Primary stability; HIGH TIBIAL OSTEOTOMY; OPEN-WEDGE OSTEOTOMY; MALLEABLE IMPLANT; DISTAL FEMUR; KNEE; COMPRESSION; FIXATION; LCP; OSTEOSYNTHESIS; FRACTURES;
D O I
10.1007/s00167-010-1281-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Little is known regarding the biomechanical stability and stiffness of implants and techniques used in supracondylar femur osteotomies (SCO). Therefore, fixation stability and stiffness of implants to bone was investigated under simulated physiological loading conditions using a composite femur model and a 3D motion-analysis system. Five osteotomy configurations were investigated: (1) oblique medial closing-wedge fixated with an angle-stable implant; (2) oblique and (3) perpendicular medial closing-wedge, both fixated with an angled blade plate; and lateral opening-wedge fixated with (4) a spacer plate and (5) an angle-stable lateral implant. The motion measured at the osteotomy was used to calculate the stiffness and stability of the constructs. The least amount of motion and highest stiffness was measured in the medial oblique closing-wedge osteotomy fixated with the angled blade plate. The lateral opening-wedge techniques were less stable and had a lower stiffness compared with the medial; the oblique saw cuts were more stable and had a higher stiffness than the perpendicular. This experimental study presents baseline data on the differences in the primary stability of bone-implant constructs used in SCO. The data in this study can be used as reference for future testing of SCO techniques. Furthermore, it is recommended that based on the differences found, the early postoperative rehabilitation protocol is tailored to the stability and stiffness of the fixation method used.
引用
收藏
页码:579 / 587
页数:9
相关论文
共 25 条
[1]
Primary stability of four different implants for opening wedge high tibial osteotomy [J].
Agneskirchner, JD ;
Freiling, D ;
Hurschler, C ;
Lobenhoffer, P .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (03) :291-300
[2]
Osteotomies around the knee PATIENT SELECTION, STABILITY OF FIXATION AND BONE HEALING IN HIGH TIBIAL OSTEOTOMIES [J].
Brinkman, J. -M. ;
Lobenhoffer, P. ;
Agneskirchner, J. D. ;
Staubli, A. E. ;
Wymenga, A. B. ;
van Heerwaarden, R. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (12) :1548-1557
[3]
Cusick R P, 2000, Am J Orthop (Belle Mead NJ), V29, P695
[4]
Reproducibility and instrument validity of a new ultrasonography-based system for measuring cervical spine kinematics [J].
Dvir, Z ;
Prushansky, T .
CLINICAL BIOMECHANICS, 2000, 15 (09) :658-664
[5]
MECHANICS OF RETROGRADE NAIL VERSUS PLATE FIXATION FOR SUPRACONDYLAR FEMUR FRACTURES [J].
FIROOZBAKHSH, K ;
BEHZADI, K ;
DECOSTER, TA ;
MONEIM, MS ;
NARAGHI, FF .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (02) :152-157
[6]
Open-wedge osteotomy of the distal femur for valgus knee [J].
Franco, V ;
Cipolla, M ;
Gerullo, G ;
Gianni, E ;
Puddu, G .
ORTHOPADE, 2004, 33 (02) :185-192
[7]
Development of the Locking Compression Plate [J].
Frigg, R .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 :6-10
[8]
Structural properties of a new design of composite replicate femurs and tibias [J].
Heiner, AD ;
Brown, TD .
JOURNAL OF BIOMECHANICS, 2001, 34 (06) :773-781
[9]
HSU RWW, 1990, CLIN ORTHOP RELAT R, P215
[10]
A SIMPLE TECHNIQUE FOR VARUS SUPRACONDYLAR OSTEOTOMY IN GENU-VALGUM [J].
LEARMONTH, ID .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (02) :235-237