Models of brachial to finger pulse wave distortion and pressure decrement

被引:113
作者
Gizdulich, P
Prentza, A
Wesseling, KH
机构
[1] TECH UNIV EINDHOVEN, DEPT ELECT ENGN, NL-5600 MB EINDHOVEN, NETHERLANDS
[2] ACAD MED CTR, TNO TPD BIOMED INSTRUMENTAT, NL-1105 AZ AMSTERDAM, NETHERLANDS
关键词
Finapres; brachial-to-finger modelling; waveform distortion; blood pressure; human;
D O I
10.1016/S0008-6363(97)00003-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Methods: Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. Results: Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. Conclusion: Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.
引用
收藏
页码:698 / 705
页数:8
相关论文
共 26 条
[21]   ANTEPARTUM CARDIOTOCOGRAPHY [J].
SMITH, CV ;
PAUL, RH .
BAILLIERES CLINICAL OBSTETRICS AND GYNAECOLOGY, 1987, 1 (01) :17-28
[22]   COMPARISON OF INTRAARTERIAL WITH CONTINUOUS NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN POSTOPERATIVE PEDIATRIC-PATIENTS [J].
TRIEDMAN, JK ;
SAUL, JP .
JOURNAL OF CLINICAL MONITORING, 1994, 10 (01) :11-20
[23]   ACCURACY OF AUSCULTATORY BLOOD-PRESSURE MEASUREMENT WITH A LONG CUFF [J].
VANMONTFRANS, GA ;
VANDERHOEVEN, GMA ;
KAREMAKER, JM ;
WIELING, W ;
DUNNING, AJ .
BRITISH MEDICAL JOURNAL, 1987, 295 (6594) :354-355
[24]   EFFECTS OF PERIPHERAL VASOCONSTRICTION ON THE MEASUREMENT OF BLOOD-PRESSURE IN A FINGER [J].
WESSELING, KH ;
SETTELS, JJ ;
VANDERHOEVEN, GMA ;
NIJBOER, JA ;
BUTIJN, MWT ;
DORLAS, JC .
CARDIOVASCULAR RESEARCH, 1985, 19 (03) :139-145
[25]  
WESSELING KH, 1995, HOMEOSTASIS HLTH DIS, V36, P67
[26]   SPECTRUM OF ORTHOSTATIC DISORDERS - CLASSIFICATION BASED ON AN ANALYSIS OF THE SHORT-TERM CIRCULATORY RESPONSE UPON STANDING [J].
WIELING, W ;
TENHARKEL, ADJ ;
VANLIESHOUT, JJ .
CLINICAL SCIENCE, 1991, 81 (02) :241-248