Organic compounds in indoor air - their relevance for perceived indoor air quality?

被引:307
作者
Wolkoff, P [1 ]
Nielsen, GD [1 ]
机构
[1] Natl Inst Occupat Hlth, DK-2100 Copenhagen O, Denmark
关键词
airway irritation; indoor air quality; OCIA; odour annoyance; TVOC; volatile organic compounds (VOCs);
D O I
10.1016/S1352-2310(01)00244-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
It is generally believed that indoor air pollution, one way or another may cause indoor air complaints. However, any association between volatile organic compounds (VOCs) concentrations and increase of indoor climate complaints, like the sick-building syndrome symptoms, is not straightforward. The reported symptom rates of, in particular, eye and upper airway irritation cannot generally be explained by our present knowledge of common chemically non-reactive VOCs measured indoors. Recently, experimental evidence has shown those chemical reactions between ozone (either with or without nitrogen dioxide) and unsaturated organic compounds (e.g. from citrus and pine oils) produce strong eye and airway irritating species. These have not yet been well characterised by conventional sampling and analytical techniques. The chemical reactions can occur indoors, and there is indirect evidence that they are associated with eye and airway irritation. However, many other volatile and non-volatile organic compounds have not generally been measured which could equally well have potent biological effects and cause an increase of complaint rates, and posses a health/comfort risk. As a consequence, it is recommended to use a broader analytical window of organic compounds than the classic VOC window as defined by the World Health Organisation. It may include hitherto not yet sampled or identified intermediary species (e.g., radicals, hydroperoxides and ionic compounds like detergents) as well as species deposited onto particles. Additionally, sampling strategies including emission testing of building products should carefully be linked to the measurement of organic compounds that are expected, based on the best available toxicological knowledge, to have biological effects at indoor concentrations. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:4407 / 4417
页数:11
相关论文
共 87 条
[11]  
Bornehag CG, 2000, P HLTH BUILD 2000 ES, V1, P437
[12]   Prevalence of the sick building syndrome symptoms in office workers before and six months and three years after being exposed to a building with an improved ventilation system [J].
Bourbeau, J ;
Brisson, C ;
Allaire, S .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1997, 54 (01) :49-53
[13]  
BRIGHTMAN HS, 2000, INDOOR AIR QUALITY H, pCH3
[14]  
Brown S.K., 1999, ORGANIC INDOOR AIR P, P171
[15]   Assessment of pollutant emissions from dry-process photocopiers [J].
Brown, SK .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (04) :259-267
[16]  
BROWN V, 1996, IEH ASSESSMENT INDOO, P152
[17]   ENVIRONMENTAL TOBACCO-SMOKE - SENSORY REACTIONS OF OCCUPANTS [J].
CAIN, WS ;
TOSUN, T ;
SEE, LC ;
LEADERER, B .
ATMOSPHERIC ENVIRONMENT, 1987, 21 (02) :347-353
[18]  
Cain WS, 1986, IAQ 86 MANAGING INDO, P126
[19]   Decomposition of terpenes by ozone during sampling on Tenax [J].
Calogirou, A ;
Larsen, BR ;
Brussol, C ;
Duane, M ;
Kotzias, D .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1499-1506
[20]   Gas chromatographic analysis of free fatty acids and fatty acid salts extracted with neutral and acidified dichloromethane from office floor dust [J].
Clausen, PA ;
Wilkins, K ;
Wolkoff, P .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :161-170