Long-term follow-up of percutaneous vena cava filters: a prospective study in 100 consecutive patients

被引:34
作者
Schleich, JM
Morla, O
Laurent, M
Langella, B
Chaperon, J
Almange, C
机构
[1] Ctr Cardiopneumol, Dept Cardiol, F-35033 Rennes 09, France
[2] Ctr Cardiopneumol, Dept Radiol, F-35033 Rennes, France
[3] Ctr Cardiopneumol, Dept Stat, F-35033 Rennes 09, France
关键词
vena cava; filters; operative procedure; extremity thrombosis; long-term follow-up;
D O I
10.1053/ejvs.2001.1319
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: the long-term outcome in following insertion of inferior venn cava (IVC) filters remains unclear, Design: prospective study. Material and Methods: one hundred consecutive patients received percutaneous vena cava fillers between 1988 and 1993. The patients underwent clinical examination, abdominal X-lays and duplex ultrasound of the IVC, right interval jugular vein and legs after a mean follow-up duration of 38 +/- 11 months. Results: forty patients died after implantation (median 11.3 months; IQR: 1.8-20.4 months). The cause of death runs known in 33 cases, and pulmonary embolism (PE) was suggested in three. Multivariate analysis revealed the mortality rate to be significantly higher in cancer patients (relative risk of 2.13). The 3-year survival was 20% for cancer patients and 71% for patients without cancer. Among the 60 living patients, thrombi were trapped in the filter in 10 cases, the filter tilted in four, was malpositioned in five and migrated in 29. These incidents were recorded as asymptomatic complications, as opposed to seven IVC thromboses and 23 recurrent lower limb thromboses, which were considered as symptomatic complications. Conclusion: long-term major complications are not frequent. As expected, cancel was the only factor predicting mortality. IVC filters seem effective in preventing PE.
引用
收藏
页码:450 / 457
页数:8
相关论文
共 37 条
[1]   SPONTANEOUS FRACTURE OF A VENA-TECH INFERIOR VENA-CAVAL FILTER [J].
AWH, MH ;
TAYLOR, FC ;
LU, CT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :177-178
[2]   The Tempofilter((R)): A multicenter study of a new temporary caval filter implantable for up to six weeks [J].
Bovyn, G ;
Gory, P ;
Reynaud, P ;
Ricco, JB .
ANNALS OF VASCULAR SURGERY, 1997, 11 (05) :520-528
[3]   Randomised trial of effect of compression stockings in patients with symptomatic proximal-vein thrombosis [J].
Brandjes, DPM ;
Buller, HR ;
Heijboer, H ;
Huisman, MV ;
deRijk, M ;
Jagt, H ;
tenCate, JW .
LANCET, 1997, 349 (9054) :759-762
[4]  
CHEN JR, 1992, CANCER, V70, P1993
[5]  
COHEN JR, 1992, CANCER, V70, P1993, DOI 10.1002/1097-0142(19921001)70:7<1993::AID-CNCR2820700731>3.0.CO
[6]  
2-V
[7]  
COHEN JR, 1991, SURGERY, V109, P12
[8]   Long-term follow-up of Vena Tech-LGM filter:: Predictors and frequency of caval occlusion [J].
Crochet, DP ;
Brunel, P ;
Trogrlic, S ;
Grossetête, R ;
Auget, JL ;
Dary, C .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (02) :137-142
[9]   VENA TECH-LGM FILTER - LONG-TERM RESULTS OF A PROSPECTIVE-STUDY [J].
CROCHET, DP ;
STORA, O ;
FERRY, D ;
GROSSETETE, R ;
LEURENT, B ;
BRUNEL, P ;
NGUYEN, JM .
RADIOLOGY, 1993, 188 (03) :857-860
[10]  
David W, 1999, AM SURGEON, V65, P341