Computer assisted navigation in total knee arthroplasty - Comparison with conventional methods

被引:176
作者
Anderson, KC
Buehler, KC
Markel, DC
机构
[1] Wayne State Univ, Providence Hosp, Detroit Med Ctr, Dept Orthopaed Surg, Detroit, MI USA
[2] Orthopaed & Neurosurg Ctr Cascades, Bend, OR USA
关键词
navigation; computer-assisted; total knee arthroplasty; mechanical alignment;
D O I
10.1016/j.arth.2005.05.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The success of knee arthroplasty is dependent on many factors. Postoperative extremity and component alignment are important determinants of outcome and longevity. Malalignment (> 3 degrees) results in higher failure rates. Computer-assisted navigation devices were developed to improve implant positioning. This study evaluated the early outcomes of a high-volume fellowship-trained surgeon relative to component positioning and limb alignment using an image-free navigation system. The navigation group consisted of 116 consecutive patients, and the conventional group consisted of 51 consecutive patients. The postoperative mechanical axis was within 3 degrees of neutral mechanical alignment in 95% of the navigation cases vs 84% of the conventional cases (P < .02). The range of the alignment and component position measurements narrowed, and the undesired outliers decreased. Accuracy was improved with navigation. Navigation was a viable device to improve the Outcome of total knee arthroplasty relative to limb and component alignment.
引用
收藏
页码:132 / 138
页数:7
相关论文
共 23 条
[1]   Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Perlick, C ;
Grifka, J .
INTERNATIONAL ORTHOPAEDICS, 2004, 28 (02) :87-90
[2]   Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[3]   Tibial component failure mechanisms in total knee arthroplasty [J].
Berend, ME ;
Ritter, MA ;
Meding, JB ;
Faris, PM ;
Keating, EM ;
Redelman, R ;
Faris, GW ;
Davis, KE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :26-34
[4]  
CATES HE, 1993, CLIN ORTHOP RELAT R, P32
[5]  
DORR LD, 1997, CLIN ORTHOP RELAT R, V205, P5
[6]  
Engh G A, 1990, J Arthroplasty, V5, P1, DOI 10.1016/S0883-5403(06)80002-1
[7]   Total knee arthroplasty implanted with and without kinematic navigation [J].
Hart, R ;
Janecek, M ;
Chaker, A ;
Bucek, P .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (06) :366-369
[8]  
INSALL JN, 1985, CLIN ORTHOP RELAT R, P13
[9]   CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[10]  
JIANG CC, 1989, CLIN ORTHOP RELAT R, P50