CT angiography of the circle of willis and intracranial internal carotid arteries: Maximum intensity projection with matched mask bone elimination-feasibility study

被引:109
作者
Venema, HW
Hulsmans, FJH
den Heeten, GJ
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Med Phys, NL-1105 AZ Amsterdam, Netherlands
关键词
aneurysms; cerebral; cerebral angiography; technology; computed tomography (CT); angiography; maximum intensity projection; images; processing;
D O I
10.1148/radiology.218.3.r01mr30893
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Results are reported of a feasibility study in which bone pixels are eliminated from computed tomographic (CT) angiographic images with a method that enables the construction of maximum intensity projection (MIP) images without interference by bone. The method proved to be successful in six patients. Two observers blinded to the bone elimination method judged the image quality of MIP images to be considerably higher than that of standard subtraction MIP images. This method is an effective means to remove bone from CT angiographic images with only a slight increase in radiation dose.
引用
收藏
页码:893 / 898
页数:6
相关论文
共 19 条
[1]   Registered image subtraction for CT-, MR- and coronary angiography [J].
Beier, J ;
Oellinger, H ;
Richter, CS ;
Fleck, E ;
Felix, R .
EUROPEAN RADIOLOGY, 1997, 7 (01) :82-89
[2]  
BEIER J, 1994, ROFO-FORTSCHR RONTG, V162, P58
[3]   SPIRAL CT ANGIOGRAPHY - AN ALTERNATIVE TO CONVENTIONAL ANGIOGRAPHY [J].
BLUEMKE, DA ;
CHAMBERS, TP .
RADIOLOGY, 1995, 195 (02) :317-319
[4]   A computer-assisted method for 3D subtraction angiography based on spiral CT [J].
Englmeier, KH ;
Fink, U ;
Haubner, M ;
Becker, C ;
Seemann, M ;
Capeller, W ;
Reiser, M .
RADIOLOGE, 1996, 36 (04) :360-364
[5]  
Gonzalez R, 1992, DIGITAL IMAGE PROCES, P518
[6]  
GORZER H, 1994, J COMPUT ASSIST TOMO, V18, P839, DOI 10.1097/00004728-199409000-00031
[7]  
Imakita S, 1998, AM J NEURORADIOL, V19, P291
[8]   Intracranial aneurysms: Detection with three-dimensional CT angiography with volume rendering - Comparison with conventional angiographic and surgical findings [J].
Korogi, Y ;
Takahashi, M ;
Katada, K ;
Ogura, Y ;
Hasuo, K ;
Ochi, M ;
Utsunomiya, H ;
Abe, T ;
Imakita, S .
RADIOLOGY, 1999, 211 (02) :497-506
[9]  
LUBOLDT W, 1997, RADIOLOGE, V31, P89
[10]   CT ANGIOGRAPHY WITH SPIRAL CT AND MAXIMUM INTENSITY PROJECTION [J].
NAPEL, S ;
MARKS, MP ;
RUBIN, GD ;
DAKE, MD ;
MCDONNELL, CH ;
SONG, SM ;
ENZMANN, DR ;
JEFFREY, RB .
RADIOLOGY, 1992, 185 (02) :607-610