CT angiography of the circle of willis and intracranial internal carotid arteries: Maximum intensity projection with matched mask bone elimination-feasibility study

被引:109
作者
Venema, HW
Hulsmans, FJH
den Heeten, GJ
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Med Phys, NL-1105 AZ Amsterdam, Netherlands
关键词
aneurysms; cerebral; cerebral angiography; technology; computed tomography (CT); angiography; maximum intensity projection; images; processing;
D O I
10.1148/radiology.218.3.r01mr30893
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Results are reported of a feasibility study in which bone pixels are eliminated from computed tomographic (CT) angiographic images with a method that enables the construction of maximum intensity projection (MIP) images without interference by bone. The method proved to be successful in six patients. Two observers blinded to the bone elimination method judged the image quality of MIP images to be considerably higher than that of standard subtraction MIP images. This method is an effective means to remove bone from CT angiographic images with only a slight increase in radiation dose.
引用
收藏
页码:893 / 898
页数:6
相关论文
共 19 条
[11]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313
[12]  
PRESS WH, 1986, NUMERICAL RECIPES, P289
[13]   EVALUATION OF CEREBRAL ANEURYSMS WITH HELICAL CT - CORRELATION WITH CONVENTIONAL ANGIOGRAPHY AND MR-ANGIOGRAPHY [J].
SCHWARTZ, RB ;
TICE, HM ;
HOOTEN, SM ;
HSU, LG ;
STIEG, PE .
RADIOLOGY, 1994, 192 (03) :717-722
[14]  
Skutta B, 1999, AM J NEURORADIOL, V20, P791
[15]   Quantitative in vivo analysis of the kinematics of carpal bones from three-dimensional CT images using a deformable surface model and a three-dimensional matching technique [J].
Snel, JG ;
Venema, HW ;
Moojen, TM ;
Ritt, MJPF ;
Grimbergen, CA ;
den Heeten, GJ .
MEDICAL PHYSICS, 2000, 27 (09) :2037-2047
[16]   MEDICAL IMAGE MATCHING - A REVIEW WITH CLASSIFICATION [J].
VANDENELSEN, PA ;
POL, EJD ;
VIERGEVER, MA .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1993, 12 (01) :26-39
[17]   AUTOMATIC 3-DIMENSIONAL CORRELATION OF CT-CT, CT-MRI, AND CT-SPECT USING CHAMFER MATCHING [J].
VANHERK, M ;
KOOY, HM .
MEDICAL PHYSICS, 1994, 21 (07) :1163-1178
[18]   CT angiography: Source images and postprocessing techniques in the detection of cerebral aneurysms [J].
Velthuis, BK ;
vanLeeuwen, MS ;
Witkamp, TD ;
Boomstra, S ;
Ramos, LMP ;
Rinkel, GJE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) :1411-1417
[19]   Petrosal bone: Coronal reconstructions from axial spiral CT data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans [J].
Venema, HW ;
Phoa, SSKS ;
Mirck, PGB ;
Hulsmans, FJH ;
Majoie, CBLM ;
Verbeeten, B .
RADIOLOGY, 1999, 213 (02) :375-382