New bone formation around porous hydroxyapatite wedge implanted in opening wedge high tibial osteotomy in patients with osteoarthritis

被引:60
作者
Koshino, T [1 ]
Murase, T [1 ]
Takagi, T [1 ]
Saito, T [1 ]
机构
[1] Yokohama City Univ, Sch Med, Dept Orthopaed Surg, Kanazawa Ku, Yokohama, Kanagawa 2360004, Japan
关键词
hydroxyapatite; bone ingrowth; osteoarthritis;
D O I
10.1016/S0142-9612(00)00318-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A porous hydroxyapatite (highly purified synthetic Ca-10(PO4)(6)(OH)(2)) wedge was inserted into the tibia in 10 knees of 7 patients with osteoarthritis of the knee who underwent high tibial osteotomy. The interface of this HA wedge with bone was histologically examined in undecalcified specimens obtained at the time of hardware removal in all 10 knees, and total incorporation of the HA into bone was observed, with no inflammatory reaction. The proportion of pores that were filled with regenerated bone within 300 mum From the interface was 71.8 +/- 10.1% (mean +/- S.D.), and it was positively correlated with the time from implantation to biopsy. Radiodensity of the HA wedge was measured during the follow-up period. and it did not change significantly within 36 months after osteotomy. Our study concluded that bone ingrowth into the HA block slowly progressed and was correlated with the passage of time. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1579 / 1582
页数:4
相关论文
共 23 条
[11]  
INOUE O, 1993, CLIN ORTHOP RELAT R, P287
[12]   ARTHROSCOPIC RESTORATION OF DEPRESSED TIBIAL PLATEAU FRACTURES USING BONE AND HYDROXYAPATITE GRAFTS [J].
ITOKAZU, M ;
MATSUNAGA, T .
ARTHROSCOPY, 1993, 9 (01) :103-108
[13]  
JARCHO M, 1981, CLIN ORTHOP RELAT R, P259
[14]   Porous ceramics as bone graft substitutes in long bone defects: A biomechanical, histological, and radiographic analysis [J].
Johnson, KD ;
Frierson, KE ;
Keller, TS ;
Cook, C ;
Scheinberg, R ;
Zerwekh, J ;
Meyers, L ;
Sciadini, MF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (03) :351-369
[15]  
KAMEGAYA M, 1993, J BONE JOINT SURG BR, V76, P123
[16]  
KOSHINO T, 1996, J E JPN ORTHOP TRAUM, V18, P603
[17]  
NEGAMI S, 1987, HIGH TECH CERAMICS, P407
[18]   Osseous tissue reaction around hydroxyapatite block implanted into proximal metaphysis of tibia of rat with collagen-induced arthritis [J].
Okazaki, A ;
Koshino, T ;
Saito, T ;
Takagi, T .
BIOMATERIALS, 2000, 21 (05) :483-487
[19]   Hydroxyapatite in revision of total hip replacements with massive acetabular defects - 4- to 10-year clinical results [J].
Oonishi, H ;
Iwaki, Y ;
Kin, N ;
Kushitani, S ;
Murata, N ;
Wakitani, S ;
Imoto, K .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (01) :87-92
[20]   Role of different loading conditions on resorption of hydroxyapatite coating evaluated by histomorphometric and stereological methods [J].
Overgaard, S ;
Soballe, K ;
Josephsen, K ;
Hansen, ES ;
Bunger, C .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (06) :888-894