摘要
A polycation-selective polymeric membrane electrode using dinonylnaphthalene sulfonate as an ion exchanger has been developed as a protamine controlled-release system for potentiometric detection of heparin. The incorporation of tetradodecylammonium tetrakis(4-chlorophenyl)borate as a lipophilic salt in the membrane dramatically improves the sensor's selectivity towards protamine over sodium ions via influencing the activity coefficient of protamine in the membrane, and a stable potential baseline can be obtained in the presence of an electrolyte background. The electrostatic binding interaction between heparin and protamine decreases the concentration of free protamine released at the sample-membrane interface and facilitates the stripping of protamine out of the membrane surface via the ion-exchange process with sodium ions, thus decreasing the membrane potential. Under optimal conditions, the proposed polymeric membrane electrode exhibits a linear relationship between the initial slope of the potential change and the heparin concentration in the range of 0.025-1.25 U mL(-1) with an improved detection limit of 0.01 U mL(-1).
引用
收藏
页码:1944 / 1949
页数:6
相关论文
共 24 条
[1]
Physical adsorption of protamine for heparin assay using a quartz crystal microbalance and electrochemical impedance spectroscopy [J].
Cheng, TJ ;
Lin, TM ;
Chang, HC .
ANALYTICA CHIMICA ACTA, 2002, 462 (02) :261-273
[2]
Potentiometric sensing of butyrylcholinesterase based on in situ generation and detection of substrates [J].
Ding, Jiawang ;
Qin, Wei .
CHEMICAL COMMUNICATIONS, 2009, (08) :971-973
[3]
Label-Free and Substrate-Free Potentiometric Aptasensing Using Polycation-Sensitive Membrane Electrodes [J].
Ding, Jiawang ;
Chen, Yan ;
Wang, Xuewei ;
Qin, Wei .
ANALYTICAL CHEMISTRY, 2012, 84 (04) :2055-2061
[4]
Current-Driven Ion Fluxes of Polymeric Membrane Ion-Selective Electrode for Potentiometric Biosensing [J].
Ding, Jiawang ;
Qin, Wei .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (41) :14640-+
[5]
EXTRACTION THERMODYNAMICS OF POLYANIONS INTO PLASTICIZED POLYMER MEMBRANES DOPED WITH LIPOPHILIC ION-EXCHANGERS - A POTENTIOMETRIC STUDY [J].
FU, B ;
BAKKER, E ;
YANG, VC ;
MEYERHOFF, ME .
MACROMOLECULES, 1995, 28 (17) :5834-5840
[6]
RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[7]
Reversible Detection of Heparin and Other Polyanions by Pulsed Chronopotentiometric Polymer Membrane Electrode [J].
Gemene, Kebede L. ;
Meyerhoff, Mark E. .
ANALYTICAL CHEMISTRY, 2010, 82 (05) :1612-1615
[8]
Voltammetric heparin-selective electrode based on thin liquid membrane with conducting polymer-modified solid support [J].
Guo, Jidong ;
Amemiya, Shigeru .
ANALYTICAL CHEMISTRY, 2006, 78 (19) :6893-6902
[9]
Highly Sensitive Potentiometric Strip Test for Detecting High Charge Density Impurities in Heparin [J].
Kang, Youngjea ;
Gwon, Kihak ;
Shin, Jae Ho ;
Nam, Hakhyun ;
Meyerhoff, Mark E. ;
Cha, Geun Sig .
ANALYTICAL CHEMISTRY, 2011, 83 (10) :3957-3962
[10]
Potentiometric sensor for heparin polyion:: Transient behavior and response mechanism [J].
Langmaier, Jan ;
Samcova, Eva ;
Samec, Zdenek .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :2892-2900