摘要
The first fully reversible polymeric membrane-based sensor for the anticoagulant heparin and other polyanions using a pulsed chronopotentiometry (pulstrode) measurement mode is reported. Polymeric membranes containing a lipophilic inert salt of the form R+R- (where R+ and R- are tridodecylmethylammonium (TDMA(+)) and dinonylnaphthalene sulfonate (DNNS-), respectively) are used to suppress unwanted spontaneous ion extractions under zero-current equilibrium conditions. An anodic galvanostatic current pulse applied across the membrane perturbs the equilibrium lipophilic ion distribution within the membrane phase in such a way that anions/polyanions are extracted into the membrane from the sample. The membrane is then subjected to an open-circuit zero current state for a short period, and finally a 0 V vs reference electrode potentiostatic pulse is applied to restore the membrane to its initial full equilibrium condition. Potentials are sampled as average values during the last 10% of the 0.5 s open circuit phase of the measurement cycle. Fully reversible and reproducible electromotive force (emf) responses are observed for heparin, pentosan polysulfate (PPS), chondroitin sulfate (CS), and over-sulfated chondroitin sulfate (OSCS), with the magnitude of the potentiometric response proportional to charge density of the polyanions. The sensor provides an emf response related to heparin concentrations in the range of 1-20 U/mL. The responses to variations in heparin levels and toward other polyanions of the pulstrode configuration are analogous to the already established single-use, nonreversible potentiometric polyion sensors based on membranes doped only with die lipophilic anion exchanger TDMA(+).
引用
收藏
页码:1612 / 1615
页数:4
相关论文
共 14 条
[1]
EXTRACTION THERMODYNAMICS OF POLYANIONS INTO PLASTICIZED POLYMER MEMBRANES DOPED WITH LIPOPHILIC ION-EXCHANGERS - A POTENTIOMETRIC STUDY [J].
FU, B ;
BAKKER, E ;
YANG, VC ;
MEYERHOFF, ME .
MACROMOLECULES, 1995, 28 (17) :5834-5840
[2]
RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[3]
Oversulfated chondroitin sulfate is a contaminant in heparin associated with adverse clinical events [J].
Guerrini, Marco ;
Beccati, Daniela ;
Shriver, Zachary ;
Naggi, Annamaria ;
Viswanathan, Karthik ;
Bisio, Antonella ;
Capila, Ishan ;
Lansing, Jonathan C. ;
Guglieri, Sara ;
Fraser, Blair ;
Al-Hakim, Ali ;
Gunay, Nur Sibel ;
Zhang, Zhenqing ;
Robinson, Luke ;
Buhse, Lucinda ;
Nasr, Moheb ;
Woodcock, Janet ;
Langer, Robert ;
Venkataraman, Ganesh ;
Linhardt, Robert J. ;
Casu, Benito ;
Torri, Giangiacomo ;
Sasisekharan, Ram .
NATURE BIOTECHNOLOGY, 2008, 26 (06) :669-675
[4]
ELECTROCHEMICAL SENSOR FOR HEPARIN - FURTHER CHARACTERIZATION AND BIOANALYTICAL APPLICATIONS [J].
MA, SC ;
YANG, VC ;
FU, B ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2078-2084
[5]
HEPARIN-RESPONSIVE ELECTROCHEMICAL SENSOR - A PRELIMINARY-STUDY [J].
MA, SC ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :694-697
[6]
Calcium pulstrodes with 10-fold enhanced sensitivity for measurements in the physiological concentration range [J].
Makarychev-Mikhailov, S ;
Shvarev, A ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2006, 78 (08) :2744-2751
[7]
Pulstrodes: Triple pulse control of potentiometric sensors [J].
Makarychev-Mikhailov, S ;
Shvarev, A ;
Bakker, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (34) :10548-10549
[8]
MEYERHOFF ME, 1995, CLIN CHEM, V41, P1355
[9]
Determination of unbiased selectivity coefficients using pulsed chronopotentiometric polymeric membrane ion sensors [J].
Perera, Hasini ;
Shvarev, Alexey .
ANALYTICAL CHEMISTRY, 2008, 80 (20) :7870-7875
[10]
Response characteristics of a reversible electrochemical sensor for the polyion protamine [J].
Shvarev, A ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2005, 77 (16) :5221-5228