Efficient foldover suppression using SENSE

被引:10
作者
Winkelmann, R
Börnert, P
Nehrke, K
Dössel, O
机构
[1] Univ Karlsruhe, Inst Biomed Engn, D-76128 Karlsruhe, Germany
[2] Philips Res Labs, D-22335 Hamburg, Germany
关键词
parallel imaging; SENSE; foldover suppression;
D O I
10.1007/s10334-004-0081-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Parallel imaging techniques, which in principle represent procedures of unfolding a reduced dataset, are well known and well established in MR imaging. This paper presents a further application of one particular reconstruction method, the SENSE algorithm, considered from a different point of view to remove potential foldover in conventional images acquired with multiple receive coils. Based on the coil sensitivity information, a body coverage map in the excited plane is calculated. This is used together with the measured raw data in a SENSE-type reconstruction to optimize the signal-to-noise ratio (SNR) as well as to remove foldover reliably by unfolding the image to a larger field of view. The reconstruction is performed automatically, without any user interaction, and does not affect data acquisition. Based on phantom and in vivo studies, which retain high image quality after the removal, the potential and limits of this approach are discussed, also taking into account future scanner hardware that will support a large number of parallel receiver channels.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 13 条
[1]  
GOLDFARB J, 2002, FIELD VIEW RESTRICTI, P2412
[2]   Artifact suppression in imaging of myocardial infarction using B1-weighted phased-array combined phase-sensitive inversion recovery [J].
Kellman, P ;
Dyke, CK ;
Aletras, AH ;
McVeigh, ER ;
Arai, AE .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) :408-412
[3]   Parallel imaging reconstruction using automatic regularization [J].
Lin, FH ;
Kwong, KK ;
Belliveau, JW ;
Wald, LL .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) :559-567
[4]  
Press W.H., 2002, NUMERICAL RECIPES C, V2nd ed
[5]  
Pruessmann K. P., 2000, Medicamundi, V44, P10
[6]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[7]  
2-S
[8]   THE NMR PHASED-ARRAY [J].
ROEMER, PB ;
EDELSTEIN, WA ;
HAYES, CE ;
SOUZA, SP ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :192-225
[9]   PROJECTION PRESATURATION .3. ACCURATE SELECTIVE EXCITATION OR PRESATURATION OF THE REGIONS OF TAILORED SHAPE IN THE PRESENCE OF SHORT-T(1) SPECIES [J].
SINGH, S ;
BRODY, WR .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1993, 101 (01) :52-62
[10]   Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays [J].
Sodickson, DK ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :591-603