Mobile-beading total knee arthroplasty - Do the polyethylene bearings rotate?

被引:58
作者
Dennis, DA
Komistek, RD
Mahfouz, MR
Outten, JT
Sharma, A
机构
[1] Univ Tennessee, Knoxville, TN USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN USA
[3] Rocky Mtn Musculoskeletal Res Lab, Denver, CO USA
关键词
D O I
10.1097/01.blo.0000185464.23505.6e
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In vivo kinematics were determined during a weightbearing deep knee bend in 39 patients implanted with four different designs of mobile-bearing total knee arthroplasty to assess polyethylene bearing mobility patterns and magnitudes. The femoral and tibial components and mobile polyethylene insert (implanted with four tantalum beads) were overlaid onto the fluoroscopic images using a three-dimensional model-fitting technique to determine bearing mobility. Three of the four designs were tested at a single time interval while one was evaluated at two postoperative intervals, (12 months apart) to assess changes in bearing mobility with time. All patients had polyethylene bearing rotation relative to the tibial tray and minimal rotation relative to the femoral component. The average maximum amounts of bearing rotation ranged from 8.4 degrees to 10.3 degrees (range, 3.0 degrees-20.1 degrees). In patients evaluated at two time intervals, the average maximum bearing rotation increased from 8.5 degrees (range, 3.4 degrees-15.5 degrees) at 3 months to 9.8 degrees (range, 48 degrees-14.1 degrees) 15 months postoperatively. The presented data demonstrates polyethylene bearing mobility occurs following mobile-bearing total knee arthroplasty and mobility is maintained during the time interval tested. The presence of bearing mobility should result in lower contact stresses reducing the potential for polyethylene wear.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 37 条
[1]  
Andriacchi T P, 1986, J Arthroplasty, V1, P211, DOI 10.1016/S0883-5403(86)80033-X
[2]  
Brantigan OC, 1941, J BONE JOINT SURG, V23, P44
[3]   Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[4]   NORMATIVE DATA OF KNEE-JOINT MOTION AND GROUND REACTION FORCES IN ADULT LEVEL WALKING [J].
CHAO, EY ;
LAUGHMAN, RK ;
SCHNEIDER, E ;
STAUFFER, RN .
JOURNAL OF BIOMECHANICS, 1983, 16 (03) :219-233
[5]  
D'Lima DD, 2001, CLIN ORTHOP RELAT R, P235
[6]   A multicenter analysis of axial femorotibial rotation after total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR ;
Walker, SA ;
Tucker, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :180-189
[7]   Multicenter determination of in vivo kinematics after total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR ;
Haas, BD ;
Stiehl, JB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :37-57
[8]   In vivo fluoroscopic analysis of fixed-bearing total knee replacements [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :114-130
[9]  
DENNIS DA, 1998, CLIN ORTHOP RELAT R, V356, P47
[10]   MOTION OF THE KNEE AFTER CONDYLAR RESURFACING - AN INVIVO STUDY [J].
ELNAHASS, B ;
MADSON, MM ;
WALKER, PS .
JOURNAL OF BIOMECHANICS, 1991, 24 (12) :1107-1117