Comparison of ampholytes used for slab gel and capillary isoelectric focusing of recombinant tissue-type plasminogen activator glycoforms.

被引:19
作者
Chen, AB
Rickel, CA
Flanigan, A
Hunt, G
Moorhouse, KG
机构
关键词
isoelectric focusing; ampholytes; gels; capillary columns; tissue plasminogen activator; proteins; glycoproteins;
D O I
10.1016/0021-9673(96)00389-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Four commercial ampholytes: Ampholine and Pharmalyte (Pharmacia Biotech), Bio-Lyte (Bio-Rad) and Servalyt (Serva) were evaluated for their ability to resolve recombinant tissue-type plasminogen activator (rt-PA) glycoforms by isoelectric focusing (IEF) and capillary IEF (cIEF). Each brand of ampholytes focused rt-PA into 3-4 major and 5-6 minor bands on slab gel electrophoresis. Visually, focused bands stained with Coomassie Blue appeared to be similarly resolved by all the ampholytes except for Ampholines, where the bands were closely grouped and more intensely stained. When cIEF was performed, Pharmalytes and Ampholines resolved rt-PA glycoforms consistent with the slab gels. No discernible peaks were detected during cIEF of rt-PA using Servalyts or Bio-Lytes. UV spectrophotometric scans of the components used for cIEF showed that Servalyts absorbed intensely over a range which overlapped the detector bandpass. Bio-Lytes showed absorption over a narrower UV range but still overlapped the detector bandpass, thus preventing the discernment of protein peaks. For this cIEF system the best ampholytes were Ampholines and Pharmalytes.
引用
收藏
页码:279 / 284
页数:6
相关论文
共 8 条
[1]   THE ROLE OF QUALITY-CONTROL IN BIOTECHNOLOGY - AN ANALYTICAL PERSPECTIVE [J].
GARNICK, RL ;
SOLLI, NJ ;
PAPA, PA .
ANALYTICAL CHEMISTRY, 1988, 60 (23) :2546-2557
[2]  
KUBACH J, 1996, 8 INT S HPCE ORL
[3]  
Mazzeo Jeff R., 1992, Methods (Orlando), V4, P205, DOI 10.1016/1046-2023(92)90035-7
[4]   Electrophoretic separation of recombinant tissue-type plasminogen activator glycoforms: Validation issues for capillary isoelectric focusing methods [J].
Moorhouse, KG ;
Rickel, CA ;
Chen, AB .
ELECTROPHORESIS, 1996, 17 (02) :423-430
[5]   RAPID ONE-STEP CAPILLARY ISOELECTRIC-FOCUSING METHOD TO MONITOR CHARGED GLYCOFORMS OF RECOMBINANT HUMAN TISSUE-TYPE PLASMINOGEN-ACTIVATOR [J].
MOORHOUSE, KG ;
EUSEBIO, CA ;
HUNT, G ;
CHEN, AB .
JOURNAL OF CHROMATOGRAPHY A, 1995, 717 (1-2) :61-69
[6]  
PRITCHETT TJ, 1994, 6 INT S HPCE SAN DIE
[7]  
THORNE JM, 1996, 8 INT S HPCE ORL
[8]   CAPILLARY ELECTROPHORESIS OF HEMOGLOBINS AND GLOBIN CHAINS [J].
ZHU, M ;
RODRIGUEZ, R ;
WEHR, T ;
SIEBERT, C .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :225-237