Pulmonary vein stenosis after radiofrequency ablation of atrial fibrillation -: Functional characterization, evolution, and influence of the ablation strategy

被引:233
作者
Saad, EB
Rossillo, A
Saad, CP
Martin, DO
Bhargava, M
Erciyes, D
Bash, D
Williams-Andrews, M
Beheiry, S
Marrouche, NF
Adams, J
Pisanò, E
Fanelli, R
Potenza, D
Raviele, A
Bonso, A
Themistoclakis, S
Brachmann, J
Saliba, WI
Schweikert, RA
Natale, A
机构
[1] Cleveland Clin Fdn, Sect Cardiac Pacing & Electrophysiol, Ctr Atrial Fibrillat, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Pulm & Crit Care Med, Cleveland, OH 44195 USA
[3] Umberto I Hosp, Dept Cardiol, Venice, Italy
[4] Marin Heart Inst, Dept Cardiol, San Francisco, CA USA
[5] Dept Cardiol, San Giovanni Rotondo, Italy
[6] Klinikum Coburg, Dept Cardiol, Coburg, Germany
关键词
fibrillation; veins; ablation; stenosis;
D O I
10.1161/01.CIR.0000104569.96907.7F
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Pulmonary vein (PV) stenosis is a complication of ablation for atrial fibrillation. The impact of different ablation strategies on the incidence of PV stenosis and its functional characterization has not been described. Methods and Results - PV isolation was performed in 608 patients. An electroanatomic approach was used in 71 and circular mapping in 537 ( distal isolation, 25; ostial isolation based on PV angiography, 102; guided by intracardiac echocardiography, 140; with energy delivery based on visualization of microbubbles, 270). Severe ( greater than or equal to 70%) narrowing was detected in 21 patients (3.4%), and moderate (50% to 69%) and mild ( < 50%) narrowing occurred in 27 (4.4%) and 47 (7.7%), respectively. Severe stenosis occurred in 15.5%, 20%, 2.9%, 1.4%, and 0%, respectively. Development of symptoms was correlated with involvement of > 1 PV with severe narrowing ( P = 0.01), whereas all patients with mild and moderate narrowing were asymptomatic. In the latter group, lung perfusion (V/ Q) scans were normal in all but 4 patients. All patients with severe stenosis had abnormal perfusion scans. Conclusions - V/ Q scans are useful to assess the functional significance of PV stenosis. Mild and moderate degrees of PV narrowing are not associated with development of symptoms and seem to have no or minimal detrimental effect on pulmonary flow. The incidence of severe PV stenosis seems to be declining with better imaging techniques to ensure ostial isolation and to guide power titration. Mild narrowing 3 months after ablation does not preclude future development of severe stenosis and should be assessed with repeat imaging studies.
引用
收藏
页码:3102 / 3107
页数:6
相关论文
共 23 条
[11]   Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation - Lessons learned by use of magnetic resonance imaging [J].
Kato, R ;
Lickfett, L ;
Meininger, G ;
Dickfeld, T ;
Wu, R ;
Juang, G ;
Angkeow, P ;
LaCorte, J ;
Bluemke, D ;
Berger, R ;
Halperin, HR ;
Calkins, H .
CIRCULATION, 2003, 107 (15) :2004-2010
[12]   Effects of operator experience on the outcome and duration of pulmonary vein isolation procedures for atrial fibrillation [J].
Knight, BP ;
Oral, H ;
Chugh, A ;
Scharf, C ;
Lai, SWK ;
Pelosi, F ;
Strickberger, SA ;
Morady, F .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (06) :673-677
[13]   Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation - Impact of different catheter technologies [J].
Marrouche, NF ;
Dresing, T ;
Cole, C ;
Bash, D ;
Saad, E ;
Balaban, K ;
Pavia, SV ;
Schweikert, R ;
Saliba, W ;
Abdul-Karim, A ;
Pisano, E ;
Fanelli, R ;
Tchou, P ;
Natale, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) :464-474
[14]   Phased-array intracardiac Echocardiography monitoring during pulmonary vein isolation in patients with atrial fibrillation - Impact on outcome and complications [J].
Marrouche, NF ;
Martin, DO ;
Wazni, O ;
Gillinov, AM ;
Klein, A ;
Bhargava, M ;
Saad, E ;
Bash, D ;
Yamada, H ;
Jaber, W ;
Schweikert, R ;
Tchou, P ;
Abdul-Karim, A ;
Saliba, W ;
Natale, A .
CIRCULATION, 2003, 107 (21) :2710-2716
[15]   Intracardiac phased-array imaging: Methods and initial clinical experience with high resolution, under blood visualization - Initial experience with intracardiac phased-array ultrasound [J].
Packer, DL ;
Stevens, CL ;
Curley, MG ;
Bruce, CJ ;
Miller, FA ;
Khandheria, BK ;
Oh, JK ;
Sinak, LJ ;
Seward, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) :509-516
[16]  
Pappone C, 2000, CIRCULATION, V102, P2619
[17]   Three-dimensional reconstruction of pulmonary veins in patients with atrial fibrillation and controls: Morphological characteristics of different veins [J].
Perez-Lugones, A ;
Schvartzman, PR ;
Schweikert, R ;
Tchou, PJ ;
Saliba, W ;
Marrouche, NF ;
Castle, LW ;
White, RD ;
Natale, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01) :8-15
[18]  
Pürerfellner H, 2003, J CARDIOVASC ELECTR, V14, P158
[19]   Intracardiac Doppler echocardiographic quantification of pulmonary vein flow velocity: An effective technique for monitoring pulmonary vein ostia narrowing during focal atrial fibrillation ablation [J].
Ren, JF ;
Marchlinski, FE ;
Callans, DJ ;
Zado, ES .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (11) :1076-1081
[20]   Pulmonary vein stenosis after catheter ablation of atrial fibrillation [J].
Robbins, IM ;
Colvin, EV ;
Doyle, TP ;
Kemp, WE ;
Loyd, JE ;
McMahon, WS ;
Kay, GN .
CIRCULATION, 1998, 98 (17) :1769-1775