Magnetic resonance lymphography in rats: Effects of muscular activity and hyperthermia on the lymph node uptake of intravenously injected superparamagnetic iron oxide particles

被引:14
作者
Elste, V
Wagner, S
Taupitz, M
Pfefferer, D
Kresse, M
Hamm, B
Berg, R
Wolf, KJ
Semmler, W
机构
[1] HUMBOLDT UNIV BERLIN, FAC MED CHARITE, INST RONTGENDIAGNOST, D-10098 BERLIN, GERMANY
[2] FREE UNIV BERLIN, UNIV KLINIKUM BENJAMIN FRANKLIN, RADIOL KLIN, BERLIN, GERMANY
[3] FREE UNIV BERLIN, INST DIAGNOST FORSCH, D-1000 BERLIN, GERMANY
[4] FREE UNIV BERLIN, INST VET ANAT HISTOL & EMBRYOL, BERLIN, GERMANY
关键词
magnetic resonance imaging; contrast media; superparamagnetic iron oxide particles; lymph nodes;
D O I
10.1016/S1076-6332(96)80193-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. We investigated the influence of muscular activity and regional body temperature changes on the accumulation of intravenously (IV) administered, dextran-coated superparamagnetic iron oxide (SPIO) particles in the lymph nodes of rats. Methods. Four groups of rats (N = 21) were used. Five rats were allowed to move freely after IV contrast administration (group 1), In another five rats, muscular inactivity (group 2) was induced during IV injection of SPIO particles and for up to 2 hr thereafter by anesthesia. In seven rats (likewise anesthetized), the contrast agent was administered while the extremities of one side of the body were warmed in a water bath for 2 hr (group 3). The rats in groups 1-3 received 100 mu mol Fe/kg of the contrast agent, Four rats not given SPIO particles served as the control group (group 4). The lymph nodes of all animals were removed 24 hr after SPIO administration and were embedded in an agar matrix for magnetic resonance imaging at 1.5 T using a proton-density-weighted spin-echo (PD-SE) sequence and a T2*-weighted gradient-recalled echo (T2* GRE) sequence. Results. Signal loss varied widely among the different lymph nodes in group 1. A pronounced signal reduction was observed in the mesenteric (PD-SE = 20 +/- 6%, T2* GRE = 55 +/- 19%), iliac (PD-SE = 13 +/- 13%, T2* GRE = 44 +/- 24%), and popliteal (PD-SE = 24 +/- 7%, T2* GRE = 70 +/- 11%) lymph nodes and only a moderate reduction in the mandibular (PD-SE = 4 +/- 7%, T2* GRE = 42 +/- 15%), axillary (PD-SE = 0 +/- 4%, T2* GRE = 8 +/- 7%), and inguinal (PD-SE = 5 +/- 5%, T2* GRE = 34 +/- 18%) lymph nodes. The least pronounced signal loss occurred in the peripheral lymph nodes of group 2, ranging from 0 +/- 3% for PD-SE sequences and 10 +/- 11% for T2* GRE sequences to 13 +/- 15% for PD-SE sequences and 41 +/- 19% for T2* GRE sequences. In group 3, the uptake of contrast material in the peripheral lymph nodes of the hyperthermal side was significantly more pronounced than on the contralateral side (p < .01), and the contrast agent was distributed more evenly to the different lymph node groups than in group 1. Conclusion. Muscular activity and regional hyperthermia markedly influence the accumulation of SPIO particles in different lymph node groups in rats. These findings must be considered in preclinical studies and in the clinical administration of MR lymphography.
引用
收藏
页码:660 / 666
页数:7
相关论文
共 24 条
[1]   INITIAL CLINICAL-EXPERIENCE WITH DEXTRAN-COATED SUPERPARAMAGNETIC IRON-OXIDE FOR DETECTION OF LYMPH-NODE METASTASES IN PATIENTS WITH HEAD AND NECK-CANCER [J].
ANZAI, Y ;
BLACKWELL, KE ;
HIRSCHOWITZ, SL ;
ROGERS, JW ;
SATO, Y ;
YUH, WTC ;
RUNGE, VM ;
MORRIS, MR ;
MCLACHLAN, SJ ;
LUFKIN, RB .
RADIOLOGY, 1994, 192 (03) :709-715
[2]  
ANZAI Y, 1994, AM J NEURORADIOL, V15, P87
[3]   BIODISTRIBUTION OF AN ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE COLLOID, BMS-180549, BY DIFFERENT ROUTES OF ADMINISTRATION [J].
BENGELE, HH ;
PALMACCI, S ;
ROGERS, J ;
JUNG, CW ;
CRENSHAW, J ;
JOSEPHSON, L .
MAGNETIC RESONANCE IMAGING, 1994, 12 (03) :433-442
[4]   TRANSPORT OF LARGE MOLECULES FROM PLASMA TO INTERSTITIAL FLUID AND LYMPH IN DOGS [J].
GARLICK, DG ;
RENKIN, EM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1970, 219 (06) :1595-&
[5]   MR LYMPHOGRAPHY WITH SUPERPARAMAGNETIC IRON NANOPARTICLES IN RATS - PATHOLOGICAL BASIS FOR CONTRAST ENHANCEMENT [J].
GUIMARAES, R ;
CLEMENT, O ;
BITTOUN, J ;
CARNOT, F ;
FRIJA, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :201-207
[6]   MR LYMPHOGRAPHY WITH IRON-OXIDE PARTICLES - DOSE-RESPONSE STUDIES AND PULSE SEQUENCE OPTIMIZATION IN RABBITS [J].
HAMM, B ;
TAUPITZ, M ;
HUSSMANN, P ;
WAGNER, S ;
WOLF, KJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (01) :183-190
[7]  
HASEGAWA M, 1978, Patent No. 4101435
[8]   PASSAGE OF UNCHARGED DEXTRANS FROM BLOOD TO LUNG LYMPH IN AWAKE SHEEP [J].
LANKEN, PN ;
HANSENFLASCHEN, JH ;
SAMPSON, PM ;
PIETRA, GG ;
HASELTON, FR ;
FISHMAN, AP .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (02) :580-591
[9]  
MADJUMDAR S, 1989, MAGNET RESON MED, V10, P289
[10]   FLOW AND COMPOSITION OF LEG LYMPH IN NORMAL MEN DURING VENOUS STASIS, MUSCULAR-ACTIVITY AND LOCAL HYPERTHERMIA [J].
OLSZEWSKI, W ;
ENGESET, A ;
JAEGER, PM ;
SOKOLOWSKI, J ;
THEODORSEN, L .
ACTA PHYSIOLOGICA SCANDINAVICA, 1977, 99 (02) :149-155