Mutual-information-based registration of medical images: A survey

被引:2015
作者
Pluim, JPW
Maintz, JBA
Viergever, MA
机构
[1] Univ Utrecht, Ctr Med, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Inst Informat & Comp Sci, NL-3508 TB Utrecht, Netherlands
关键词
image registration; literature survey; matching; mutual information;
D O I
10.1109/TMI.2003.815867
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An overview is presented of the medical image processing literature on mutual-information-based registration. The aim of the survey is threefold: an introduction for those new to the field, an overview for those working in the field, and a reference for those searching for literature on a specific application. Methods are classified according to the different aspects of mutual-information-based registration. The main division is in aspects of the methodology and of the application. The part on methodology describes choices made on facets such as preprocessing of images, gray value interpolation, optimization, adaptations to the mutual information measure, and different types of geometrical transformations. The part on applications is a reference of the literature available on different modalities, on interpatient registration and on different anatomical objects. Comparison studies including mutual information are also considered. The paper starts with a description of entropy and mutual information and it closes with a discussion on past achievements and some future challenges.
引用
收藏
页码:986 / 1004
页数:19
相关论文
共 169 条
[41]  
HELLIER P, 2001, LECT NOTES COMPUTER, P258
[42]  
HERMOSILLO G, 2001, COMPUTER VISION PATT, V1, P73
[43]  
Hill D. L. G., 1993, Information Processing in Medical Imaging. 13th International Conference, IPMI '93 Proceedings, P182, DOI 10.1007/BFb0013788
[44]   Measurement of intraoperative brain surface deformation under a craniotomy [J].
Hill, DLG ;
Maurer, CR ;
Maciunas, RJ ;
Barwise, JA ;
Fitzpatrick, JM ;
Wang, MY .
NEUROSURGERY, 1998, 43 (03) :514-526
[45]   Medical image registration [J].
Hill, DLG ;
Batchelor, PG ;
Holden, M ;
Hawkes, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :R1-R45
[46]  
Hill DLG, 1999, LECT NOTES COMPUT SC, V1679, P910
[47]   Correcting scaling errors in tomographic images using a nine degree of freedom registration algorithm [J].
Hill, DLG ;
Maurer, CR ;
Studholme, C ;
Fitzpatrick, JM ;
Hawkes, DJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (02) :317-323
[48]  
HILL DLG, 1994, P SOC PHOTO-OPT INS, V2359, P205
[49]   Voxel similarity measures for 3-D serial MR brain image registration [J].
Holden, M ;
Hill, DLG ;
Denton, ERE ;
Jarosz, JM ;
Cox, TCS ;
Rohlfing, T ;
Goodey, J ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (02) :94-102
[50]   Detecting small anatomical change with 3D serial MR subtraction images [J].
Holden, M ;
Denton, ERE ;
Jarosz, JM ;
Cox, TCS ;
Studholme, C ;
Hawkes, DJ ;
Hill, DLG .
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 :44-55