Monte Carlo simulation of a computed tomography x-ray tube

被引:55
作者
Bazalova, Magdalena [1 ]
Verhaegen, Frank [1 ]
机构
[1] McGill Univ, Montreal Gen Hosp, Dept Med Phys, Montreal, PQ H3G 1A4, Canada
关键词
D O I
10.1088/0031-9155/52/19/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The dose delivered to patients during computed tomography ( CT) exams has increased in the past decade. With the increasing complexity of CT examinations, measurement of the dose becomes more difficult and more important. In some cases, the standard methods, such as measurement of the computed tomography dose index ( CTDI), are currently under question. One approach to determine the dose from CT exams is to use Monte Carlo ( MC) methods. Since the patient geometry can be included in the model, Monte Carlo simulations are potentially the most accurate method of determining the dose delivered to patients. In this work, we developed a MC model of a CT x-ray tube. The model was validated with half-value layer ( HVL) measurements and spectral measurements with a high resolution Schottky CdTe spectrometer. First and second HVL for beams without additional filtration calculated from the MC modelled spectra and determined from attenuation measurements differ by less than 2.5%. The differences between the first and second HVL for both filtered and non-filtered beams calculated from the MC modelled spectra and spectral measurements with the CdTe detector were less than 1.8%. The MC modelled spectra match the directly measured spectra. This works presents a first step towards an accurate MC model of a CT scanner.
引用
收藏
页码:5945 / 5955
页数:11
相关论文
共 22 条
[11]   A COMPTON-SCATTERING SPECTROMETER FOR DETERMINING X-RAY PHOTON ENERGY-SPECTRA [J].
MATSCHEKO, G ;
RIBBERFORS, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (05) :577-594
[12]   Thin CdTe detector in diagnostic x-ray spectroscopy [J].
Miyajima, S .
MEDICAL PHYSICS, 2003, 30 (05) :771-777
[13]   Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scanner [J].
Mori, S. ;
Nishizawa, K. ;
Ohno, M. ;
Endo, M. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (947) :888-892
[15]   (HP)Ge measurement of spectra for diagnostic X-ray beams [J].
Nogueira, MS ;
Mota, HC ;
Campos, LL .
RADIATION PROTECTION DOSIMETRY, 2004, 111 (01) :105-110
[16]  
REHANI MM, 2001, 87 ANN ICRP REP, V30
[17]   RELATIONSHIP OF RELATIVISTIC COMPTON CROSS-SECTION TO MOMENTUM DISTRIBUTION OF BOUND ELECTRON STATES [J].
RIBBERFORS, R .
PHYSICAL REVIEW B, 1975, 12 (06) :2067-2074
[18]   BEAM - A MONTE-CARLO CODE TO SIMULATE RADIOTHERAPY TREATMENT UNITS [J].
ROGERS, DWO ;
FADDEGON, BA ;
DING, GX ;
MA, CM ;
WE, J ;
MACKIE, TR .
MEDICAL PHYSICS, 1995, 22 (05) :503-524
[19]  
SELTZER SM, 1981, NUCL INSTRUM METHODS, V188, P133, DOI 10.1016/0029-554X(81)90332-3
[20]   Monte Carlo modelling of radiotherapy kV x-ray units [J].
Verhaegen, F ;
Nahum, AE ;
Van de Putte, S ;
Namito, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (07) :1767-1789